ROUTINE HELICAL CT OF THE ABDOMEN - IMAGE QUALITY CONSIDERATIONS

被引:40
作者
ZEMAN, RK
ZEIBERG, AS
DAVROS, WJ
ASCHER, SM
COOPER, CJ
WELTMAN, DI
PATT, R
GARRA, BS
GRIEGO, DL
SILVERMAN, PM
机构
[1] Department of Radiology, Georgetown University Medical Center, Washington, DC 20007
关键词
ABDOMEN; CT; COMPUTED TOMOGRAPHY (CT); HELICAL TECHNOLOGY; IMAGE QUALITY;
D O I
10.1148/radiology.189.2.8210365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Both helical and nonhelical abdominal computed tomographic (CT) scans were obtained to compare image quality, study the effect of patient size and collimation, and compare the frequency of visualization of normal abdominal structures. MATERIALS AND METHODS: The study group consisted of 60 consecutive patients with clinically suspected metastatic malignancy. RESULTS: Both helical and nonhelical image quality was excellent, with equal mean image quality scores of 4.1 on a 5-point scale. In patients weighing more than 175 lb (79 kg), both helical and nonhelical image quality degraded equally when 5-mm collimation was used; 10-mm collimation resulted in excellent image quality, regardless of patient size. Small in-plane structures (eg, renal arteries, renal veins, pancreatic duct) were seen best on helical scans. With the addition of retrospectively reconstructed overlapping images, improvement in visualization of these structures was statistically significant. CONCLUSION: Helical CT scanning should be the preferred means of acquiring routine abdominal CT images.
引用
收藏
页码:395 / 400
页数:6
相关论文
共 9 条
  • [1] SPIRAL CT - DECREASED SPATIAL-RESOLUTION INVIVO DUE TO BROADENING OF SECTION-SENSITIVITY PROFILE
    BRINK, JA
    HEIKEN, JP
    BALFE, DM
    SAGEL, SS
    DICROCE, J
    VANNIER, MW
    [J]. RADIOLOGY, 1992, 185 (02) : 469 - 474
  • [2] COMPUTED-TOMOGRAPHY SCANNING WITH SIMULTANEOUS PATIENT TRANSLATION
    CRAWFORD, CR
    KING, KF
    [J]. MEDICAL PHYSICS, 1990, 17 (06) : 967 - 982
  • [3] DANIEL WW, 1987, BIOSTATISTICS F ANAL, P273
  • [4] SPIRAL CT OF THE PANCREAS
    DUPUY, DE
    COSTELLO, P
    ECKER, CP
    [J]. RADIOLOGY, 1992, 183 (03) : 815 - 818
  • [5] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [6] EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT
    POLACIN, A
    KALENDER, WA
    MARCHAL, G
    [J]. RADIOLOGY, 1992, 185 (01) : 29 - 35
  • [7] INITIAL EXPERIENCE WITH VOLUME CT SCANNING
    RIGAUTS, H
    MARCHAL, G
    BAERT, AL
    HUPKE, R
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) : 675 - 682
  • [8] URBAN A, 1993, AJR, V160, P783
  • [9] HELICAL (SPIRAL) CT OF THE ABDOMEN
    ZEMAN, RK
    FOX, SH
    SILVERMAN, PM
    DAVROS, WJ
    CARTER, LM
    GRIEGO, D
    WELTMAN, DI
    ASCHER, SM
    COOPER, CJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (04) : 719 - 725