EFFECTS OF REUSE ON THE PHYSICAL CHARACTERISTICS OF ANGIOGRAPHIC CATHETERS

被引:10
作者
BENTOLILA, P
JACOB, R
ROBERGE, F
机构
[1] ECOLE POLYTECH,INST GENIE BIOMED,MONTREAL H3C 3A7,QUEBEC,CANADA
[2] UNIV MONTREAL,MONTREAL H3C 3J7,QUEBEC,CANADA
关键词
D O I
10.3109/03091909009015433
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Five types of angiographic catheters used in current radiological and haemodynamic clinical practice at Sacre-Coeur Hospital in Montreal were studied for their mechanical sturdiness, and also with respect to the possibility that re-use could be associated with blood contamination by loose particles. Samples were taken both from new catheters and from catheters re-used up to 10 times. Routine cleaning and sterilization procedures showed no adverse effects on the maximum tensile strength and elongation at break of catheters. While some biological debris were occasionally present in re-used catheters, they appeared to be firmly fixed to the lumen surface, and they seemed unlikely to be carried into the blood stream during catheterization. On the other hand, new catheters exhibited a substantially higher loose particicle count than catheters which had been properly cleaned and sterilized. It is concluded that properly handled re-used angiographic catheters are just as safe for the patient as new catheters. The limit on the number of re-uses may depend on the care taken to avoid damage to the lumen surface during cleaning, on ageing on the catheter material and on economic considerations.
引用
收藏
页码:254 / 259
页数:6
相关论文
共 9 条
[1]   SCANNING ELECTRON-MICROSCOPIC STUDY OF ANGIOGRAPHIC CATHETERS AND GUIDE WIRES [J].
ANDERSON, JH ;
GIANTURCO, C ;
WALLACE, S ;
DODD, GD .
RADIOLOGY, 1974, 111 (03) :567-571
[2]  
BOURKE J, 1968, INT J CARDIOL, V12, P359
[3]   SEQUENTIAL STUDY OF LEFT-VENTRICULAR FUNCTION IN AORTIC VALVULAR STENOSIS [J].
CHA, SD ;
NAEEM, SM ;
MARANHAO, V ;
GOOCH, AS .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (02) :145-154
[4]  
GOURR L, 1987, PHARMACOPEIAL FORUM, P2506
[5]   FEVER, CHILLS, AND HYPOTENSION FOLLOWING CARDIAC-CATHETERIZATION WITH SINGLE-USE AND MULTIPLE-USE DISPOSABLE CATHETERS [J].
JACOBSON, JA ;
SCHWARTZ, CE ;
MARSHALL, HW ;
CONTI, M ;
BURKE, JP .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1983, 9 (01) :39-46
[6]   CATHETER SEPARATION DURING CARDIAC-CATHETERIZATION AND CORONARY ANGIOGRAPHY - A REPORT OF 4 INCIDENTS AND REVIEW OF THE LITERATURE [J].
KYRIAKIDES, ZS ;
BELLENIS, IP ;
CARALIS, DG .
ANGIOLOGY, 1986, 37 (10) :762-765
[7]   REUSE OF DISPOSABLE CATHETERS AND GUIDE WIRES [J].
RAVIN, CE ;
KOEHLER, PR .
RADIOLOGY, 1977, 122 (03) :577-579
[8]  
SABOURIN P, 1988, REV EUROPEENNE TECHN, V10, P154
[9]   EFFECTS OF DSIP IN MAN - MULTIFUNCTIONAL PSYCHOPHYSIOLOGICAL PROPERTIES BESIDES INDUCTION OF NATURAL SLEEP [J].
SCHNEIDERHELMERT, D ;
SCHOENENBERGER, GA .
NEUROPSYCHOBIOLOGY, 1983, 9 (04) :197-206