A RELIABLE TECHNIQUE FOR CHRONIC CAROTID ARTERIAL CATHETERIZATION IN THE RAT

被引:19
作者
TSUI, BCH [1 ]
MOSHER, SJ [1 ]
YEUNG, PKF [1 ]
机构
[1] DALHOUSIE UNIV,FAC HLTH PROFESS,COLL PHARM,HALIFAX B3H 3J5,NS,CANADA
来源
JOURNAL OF PHARMACOLOGICAL METHODS | 1991年 / 25卷 / 04期
基金
英国医学研究理事会;
关键词
RATS; CAROTID ARTERY; CHRONIC BLOOD SAMPLING; BLOOD PRESSURE MEASUREMENT;
D O I
10.1016/0160-5402(91)90033-2
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A reliable and simple method for cannulating the carotid artery of rats is described. The rat was anesthetized with halothane. The right carotid artery located between the omohyoideus and sternohyoideus muscles was exposed through a 2-cm ventral neck incision. The catheter was made of Silastic tubing and a monofilament line, which served as an obturator and internal support. The line was then filled with a viscous mixture of heparin, polyvinylpyrrolidinone and normal saline to prevent the formation of blood clots. The catheter was advanced through the carotid artery towards the heart by a predetermined distance (15-20 mm) depending on the size of the rat. The catheter was well tolerated by the rats and the success rate was 95%. Its patency lasted for at least 7 days postsurgery without any special maintenance care. With the described method one would be able to perform repetitive blood sampling and arterial blood pressure measurements in unanesthetized and unrestrained rats for prolonged period after catheterization.
引用
收藏
页码:343 / 352
页数:10
相关论文
共 12 条
[1]   DIRECT RECORDING OF ARTERIAL BLOOD-PRESSURE AND HEART-RATE IN CONSCIOUS RAT [J].
ANDREWS, DI ;
JONES, DR ;
SIMPSON, FO .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1978, 30 (08) :524-525
[2]  
BRENNER U, 1985, LAB ANIM, V15, P192
[3]  
GISVOLD O, 1962, TXB ORGANIC MED PHAR, P751
[4]  
Hansen A. T., 1949, ACTA PHYSIOL SCA S68, V19, P1
[5]   A SIMPLIFIED CANNULATION PROCEDURE FOR PHARMACOKINETIC EXPERIMENTS IN RATS [J].
JONGEN, MJ ;
NORMAN, AW .
JOURNAL OF PHARMACOLOGICAL METHODS, 1987, 17 (03) :271-275
[6]  
MCDONALD DA, 1974, BLOOD FLOW ARTERIES, P174
[7]  
PARKER GW, 1909, LAB ANIM SCI, V39, P463
[8]   PERMANENT CANNULATION OF AORTA AND VENA CAVA IN RATS AND GROUND SQUIRRELS [J].
POPOVIC, V ;
POPOVIC, P .
JOURNAL OF APPLIED PHYSIOLOGY, 1960, 15 (04) :727-728
[9]   MEASUREMENT OF BLOOD-PRESSURE IN UNRESTRAINED RATS [J].
ROSS, AR .
PHYSIOLOGY & BEHAVIOR, 1977, 19 (02) :327-329
[10]   CHRONIC INTRAVENOUS CANNULATION TECHNIQUE ADAPTED FOR BEHAVIORAL-STUDIES [J].
TERKEL, J ;
URBACH, L .
HORMONES AND BEHAVIOR, 1974, 5 (02) :141-148