ASSESSMENT OF THE HUMAN CORONARY CIRCULATION USING A DOPPLER CATHETER

被引:39
作者
WILSON, RF
机构
[1] UNIV MINNESOTA, DEPT MED, MINNEAPOLIS, MN 55455 USA
[2] UNIV MINNESOTA, MINNESOTA HEART & LUNG INST, MINNEAPOLIS, MN 55455 USA
关键词
D O I
10.1016/S0002-9149(05)80007-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arteriographic estimates of stenosis severity can fail to reflect the impact of an individual stenosis on delivery of blood to the myocardium. Whether a coronary stenosis is truly flow-limiting can be determined by measuring hyperemic blood flow or coronary flow reserve; however, until recently, the tools needed to measure coronary flow reserve in humans-namely, a method of quantitating coronary blood flow in individual arteries and another method for producing maximal microvascular vasodilation-were not available. Over the last 8 years, our laboratory group has developed a catheter for measuring coronary blood flow velocity in humans, using the Doppler principle, and studied the effects of microvascular vasodilators. These studies have enabled us to measure coronary flow reserve in humans and to characterize some of the effects of focal and diffuse atherosclerosis on the coronary circulation. In addition, we have used flow reserve measurements in the diagnosis of microvascular dysfunction in patients with chest pain and normal coronary arteries and as a means of assessing noninvasive methods for detecting focal coronary artery disease.
引用
收藏
页码:D44 / D56
页数:13
相关论文
共 43 条
[1]   CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS [J].
ARNETT, EN ;
ISNER, JM ;
REDWOOD, DR ;
KENT, KM ;
BAKER, WP ;
ACKERSTEIN, H ;
ROBERTS, WC .
ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) :350-356
[2]   CONDITIONS FOR VASODILATOR-INDUCED CORONARY STEAL IN EXPERIMENTAL MYOCARDIAL ISCHEMIA [J].
BECKER, LC .
CIRCULATION, 1978, 57 (06) :1103-1110
[3]   NEW METHOD TO MEASURE PHASIC CORONARY BLOOD VELOCITY IN MAN [J].
BENCHIMOL, A ;
STEGALL, HF ;
GARTLAN, JL .
AMERICAN HEART JOURNAL, 1971, 81 (01) :93-+
[4]   PROLONGED IMPAIRMENT OF CORONARY VASODILATION AFTER REVERSIBLE ISCHEMIA - EVIDENCE FOR MICROVASCULAR STUNNING [J].
BOLLI, R ;
TRIANA, JF ;
JEROUDI, MO .
CIRCULATION RESEARCH, 1990, 67 (02) :332-343
[5]   COMPARATIVE EFFICACY OF CORONARY VASODILATORY METHODS [J].
BOOKSTEIN, JJ ;
HIGGINS, CB .
INVESTIGATIVE RADIOLOGY, 1977, 12 (02) :121-127
[6]   ANGINA DUE TO CORONARY MICROVASCULAR DISEASE IN HYPERTENSIVE PATIENTS WITHOUT LEFT-VENTRICULAR HYPERTROPHY [J].
BRUSH, JE ;
CANNON, RO ;
SCHENKE, WH ;
BONOW, RO ;
LEON, MB ;
MARON, BJ ;
EPSTEIN, SE .
NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (20) :1302-1307
[7]   REDISTRIBUTION OF CORONARY MICROVASCULAR RESISTANCE PRODUCED BY DIPYRIDAMOLE [J].
CHILIAN, WM ;
LAYNE, SM ;
KLAUSNER, EC ;
EASTHAM, CL ;
MARCUS, ML .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 256 (02) :H383-H390
[8]   MICROVASCULAR DISTRIBUTION OF CORONARY VASCULAR-RESISTANCE IN BEATING LEFT-VENTRICLE [J].
CHILIAN, WM ;
EASTHAM, CL ;
MARCUS, ML .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (04) :H779-H788
[9]   PULSED DOPPLER CORONARY-ARTERY CATHETER - PRELIMINARY-REPORT OF A NEW TECHNIQUE FOR MEASURING RAPID CHANGES IN CORONARY-ARTERY FLOW VELOCITY IN MAN [J].
COLE, JS ;
HARTLEY, CJ .
CIRCULATION, 1977, 56 (01) :18-25
[10]   INCREASED MYOCARDIAL PERFUSION AT REST AND DIMINISHED PERFUSION RESERVE IN PATIENTS WITH ANGINA AND ANGIOGRAPHICALLY NORMAL CORONARY-ARTERIES [J].
GELTMAN, EM ;
HENES, CG ;
SENNEFF, MJ ;
SOBEL, BE ;
BERGMANN, SR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (03) :586-595