DYNAMIC EQUIVALENT OF AN INDUSTRIAL INDUCTION-MOTOR LOAD BY PARAMETER IDENTIFICATION

被引:3
作者
RICHARDS, GG [1 ]
TAN, OT [1 ]
机构
[1] LOUISIANA STATE UNIV,DEPT ELECT ENGN,BATON ROUGE,LA 70803
来源
ARCHIV FUR ELEKTROTECHNIK | 1979年 / 61卷 / 05期
关键词
D O I
10.1007/BF01579193
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A method is proposed to represent an induction motor group by a third order nonlinear model of an equivalent induction machine for transient stability studies. The equivalent motor and load parameters are obtained by a parameter identification technique which requires no knowledge of the individual machine and load parameters of the motor group beyond its overall current response to a voltage dip field test. With a simulated four induction motor group representing a statistically typical industrial load, the equivalent machine is shown to predict satisfactorily the machine group behavior under power system fault conditions. © 1979 Springer-Verlag.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 11 条
[1]  
BERG GJ, 1971, MODEL REPRESENTATION, P153
[2]   HIGH-EFFICIENCY MOTORS FOR SEVERE DUTY ENVIRONMENTS [J].
BILLER, CG .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1978, 14 (04) :347-351
[3]  
BRERETON DS, 1957, AIEE T POWER APPARAT, V76, P451
[4]   TRANSIENT LOAD MODEL OF AN INDUCTION-MOTOR [J].
CATHEY, JJ ;
CAVIN, RK .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (04) :1399-1406
[5]  
Eykhoff P., 1974, SYSTEM IDENTIFICATIO, V1st ed.
[6]  
HAKIM MM, 1976, IEEE T POWER APP SYS, V76, P155
[7]  
ILICETO F, 1972, IEEE T POWER APP SYS, V72, P2470
[8]  
ILLICETO F, 1974, IEEE T PAS, V93, P1650
[9]   THEORY OF NEGLECTING STATOR TRANSIENTS [J].
KRAUSE, PC ;
NOZARI, F ;
SKVARENINA, TL ;
OLIVE, DW .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (01) :141-148
[10]   WEIGHTED-LEAST-SQUARES PARAMETER ESTIMATOR FOR SYNCHRONOUS MACHINES [J].
LEE, CC ;
TAN, OT .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (01) :97-101