CONTRIBUTION OF D-DIMER PLASMA MEASUREMENT AND LOWER-LIMB VENOUS ULTRASOUND TO THE DIAGNOSIS OF PULMONARY-EMBOLISM - A DECISION-ANALYSIS MODEL

被引:42
作者
PERRIER, A
BOUNAMEAUX, H
MORABIA, A
DEMOERLOOSE, P
SLOSMAN, D
UNGER, PF
JUNOD, A
机构
[1] UNIV HOSP GENEVA, DIV PNEUMOL, GENEVA, SWITZERLAND
[2] UNIV HOSP GENEVA, DIV ANGIOL & HEMOSTASIS, GENEVA, SWITZERLAND
[3] UNIV HOSP GENEVA, CLIN EPIDEMIOL UNIT, GENEVA, SWITZERLAND
[4] UNIV HOSP GENEVA, DIV NUCL MED, GENEVA, SWITZERLAND
[5] UNIV HOSP GENENVA, MED CLIN 1, GENEVA, SWITZERLAND
[6] UNIV HOSP GENEVA, CTR MEDICOCHIRURG ENTREES, GENEVA, SWITZERLAND
基金
新加坡国家研究基金会;
关键词
D O I
10.1016/0002-8703(94)90673-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study has shown that clinical evaluation and lung scanning may substantiate or exclude pulmonary embolism with reasonable probability in approximately half of the patients in whom it is suspected; for the remainder, pulmonary angiography is considered the gold standard diagnostic test. We performed a decision analysis io assess the potential of two noninvasive tests,D-dimer plasma measurement and lower-limb B-mode venous ultrasound, for reducing the number of pulmonary angiograms necessary to diagnose pulmonary embolism. Our decision model addresses hypothetical patients in the emergency ward with suspected pulmonary embolism and abnormal lung scan results. Results show that D-dimer measurements of less than 500 mu g/L could be used reliably to exclude pulmonary embolism:in patients with an abnormal but not high-probability (inconclusive) lung scan. D-dimer measurements of greater than 500 mu g/L have no positive predictive value for pulmonary embolism and should be followed by ultrasound, which may replace pulmonary angiography when it discloses deep venous thrombosis. Pulmonary angiography should be performed when ultrasound is negative because of its presumably low sensitivity for deep venous thrombosis in patients with pulmonary embolism. A D-dimer measurement of less than 500 mu/L does not exclude pulmonary embolism in patients with a high clinical suspicion of pulmonary embolism. On the basis of the results of the PIOPED study, we calculated that the combination of D-dimer measurement and ultrasound might reduce the requirement for pulmonary angiography by one third among patients with inconclusive scan results and intermediate clinical probability of pulmonary embolism.
引用
收藏
页码:624 / 635
页数:12
相关论文
共 40 条
[1]  
AGNELLI G, 1992, THROMB HAEMOSTASIS, V68, P257
[2]   PULMONARY-EMBOLISM - DIAGNOSIS WITH MULTIPLE IMAGING MODALITIES [J].
ALDERSON, PO ;
MARTIN, EC .
RADIOLOGY, 1987, 164 (02) :297-312
[3]   MORTALITY IN PATIENTS TREATED FOR PULMONARY-EMBOLISM [J].
ALPERT, JS ;
SMITH, R ;
CARLSON, CJ ;
OCKENE, IS ;
DEXTER, L ;
DALEN, JE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 236 (13) :1477-1480
[4]   A POPULATION-BASED PERSPECTIVE OF THE HOSPITAL INCIDENCE AND CASE-FATALITY RATES OF DEEP-VEIN THROMBOSIS AND PULMONARY-EMBOLISM - THE WORCESTER DVT STUDY [J].
ANDERSON, FA ;
WHEELER, HB ;
GOLDBERG, RJ ;
HOSMER, DW ;
PATWARDHAN, NA ;
JOVANOVIC, B ;
FORCIER, A ;
DALEN, JE .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (05) :933-938
[5]   DEEP VENOUS THROMBOSIS OF THE LEG - UNITED-STATES FINDINGS [J].
APPELMAN, PT ;
DEJONG, TE ;
LAMPMANN, LE .
RADIOLOGY, 1987, 163 (03) :743-746
[6]  
BARRITT DW, 1960, LANCET, V1, P1309
[7]   REAL-TIME ULTRASONOGRAPHY FOR THE DIAGNOSIS OF LOWER-EXTREMITY DEEP VENOUS THROMBOSIS - THE WAVE OF THE FUTURE [J].
BECKER, DM ;
PHILBRICK, JT ;
ABBITT, PL .
ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (08) :1731-1734
[8]   MEASUREMENT OF D-DIMER IN PLASMA AS DIAGNOSTIC-AID IN SUSPECTED PULMONARY-EMBOLISM [J].
BOUNAMEAUX, H ;
CIRAFICI, P ;
DEMOERLOOSE, P ;
SCHNEIDER, PA ;
SLOSMAN, D ;
REBER, G ;
UNGER, PF .
LANCET, 1991, 337 (8735) :196-200
[9]  
Bounameaux H, 1990, Blood Coagul Fibrinolysis, V1, P577, DOI 10.1097/00001721-199010000-00045
[10]  
BOUNAMEAUX H, 1988, LANCET, V2, P628