TEST-RETEST VARIABILITY OF TOPOGRAPHIC MEASUREMENTS WITH CONFOCAL SCANNING LASER TOMOGRAPHY IN PATIENTS WITH GLAUCOMA AND CONTROL SUBJECTS

被引:171
作者
CHAUHAN, BC [1 ]
LEBLANC, RP [1 ]
MCCORMICK, TA [1 ]
ROGERS, JB [1 ]
机构
[1] DALHOUSIE UNIV, DEPT OPHTHALMOL, HALIFAX, NS, CANADA
基金
英国医学研究理事会;
关键词
D O I
10.1016/S0002-9394(14)72836-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Using confocal scanning laser tomography, we studied the test-retest variability of topographic measurements of the optic nerve head and parapapillary retina in 30 patients with glaucoma and 30 normal control subjects. We obtained three independent images, separated by between one and six hours, centered on the optic nerve head. We condensed each original 256 x 256-pixel image to a 64 x 64-pixel image, thereby allowing a realistic estimate of the empiric 90% confidence interval of test-retest variability at each condensed pixel. Confidence interval maps generated for each subject showed highest measurement variability along the cup border and blood vessels. The mean standard deviation equivalents of test-retest variability in the patients and controls were 31.20 and 25.94 mu m respectively. These differences were statistically significant (P = .010). Variability increased with age (P < .001), When the analysis was repeated for discrete parapapillary areas, the group differences were not statistically significant (P = .100).
引用
收藏
页码:9 / 15
页数:7
相关论文
共 16 条
[1]   CONFOCAL LASER TOMOGRAPHIC ANALYSIS OF THE RETINA IN EYES WITH MACULAR HOLE FORMATION AND OTHER FOCAL MACULAR DISEASES [J].
BARTSCH, DU ;
INTAGLIETTA, M ;
BILLE, JF ;
DREHER, AW ;
GHARIB, M ;
FREEMAN, WR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1989, 108 (03) :277-287
[2]  
CAPRIOLI J, 1986, ARCH OPHTHALMOL-CHIC, V104, P1035
[3]  
CIOFFI GA, 1993, OPHTHALMOLOGY, V100, P57
[4]  
Cornsweet T. N., 1983, Advances in Diagnostic Visual Optics. Proceedings of the Second International Symposium, P141
[5]   VARIABILITY OF DEPTH MEASUREMENTS OF THE OPTIC-NERVE HEAD AND PERIPAPILLARY RETINA WITH COMPUTERIZED IMAGE-ANALYSIS [J].
DANDONA, L ;
QUIGLEY, HA ;
JAMPEL, HD .
ARCHIVES OF OPHTHALMOLOGY, 1989, 107 (12) :1786-1792
[6]   REPRODUCIBILITY OF TOPOGRAPHIC MEASUREMENTS OF THE NORMAL AND GLAUCOMATOUS OPTIC-NERVE HEAD WITH THE LASER TOMOGRAPHIC SCANNER [J].
DREHER, AW ;
TSO, PC ;
WEINREB, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (02) :221-229
[7]  
KRUSE FE, 1989, OPHTHALMOLOGY, V96, P1320
[8]  
Lusky M, 1993, J Glaucoma, V2, P104
[9]  
Mikelberg F S, 1993, J Glaucoma, V2, P101
[10]   RELIABILITY OF OPTIC DISK TOPOGRAPHIC MEASUREMENTS RECORDED WITH VIDEO-OPHTHALMOGRAPH [J].
MIKELBERG, FS ;
DOUGLAS, GR ;
SCHULZER, M ;
CORNSWEET, TN ;
WIJSMAN, K .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 98 (01) :98-102