COMPARISON OF A CAVITY SOLAR RECEIVER NUMERICAL-MODEL AND EXPERIMENTAL-DATA

被引:21
作者
HOGAN, RE
DIVER, RB
STINE, WB
机构
[1] SANDIA NATL LABS,DEPT SOLAR ENERGY,ALBUQUERQUE,NM 87185
[2] CALIFORNIA STATE POLYTECH UNIV,DEPT MECH ENGN,POMONA,CA 91768
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 1990年 / 112卷 / 03期
关键词
D O I
10.1115/1.2930478
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Results from a numerical model of axisymmetric solar cavity receivers are compared with experimental data for tests of a novel test bed receiver in the Sandia National Laboratories solar furnace. The computed energy transfer rates and temperatures are compared with the experimental data for different receiver geometries, aperture sizes, and operating conditions. In general, the agreement between the numerical model and the experimental data is better for the small-to-midsized apertures than for the large apertures. The analysis indicates that for the larger apertures, the convective heat losses are overpredicted. It also suggests that these losses could be better characterized. Sensitivity analyses show that both the total solar energy input rate and the convective heat-loss coefficient significantly affect the receiver thermal performance and that the distribution of the input solar flux significantly affects the temperature distribution in the receiver. © 1990 by ASME.