MASSIVE AIR EMBOLI FROM INTRAVENOUS-INFUSION PUMP - ETIOLOGY AND PREVENTION

被引:13
作者
ABERNATHY, CM [1 ]
DICKINSON, TC [1 ]
机构
[1] MONTROSE MEM HOSP,MONTROSE,CO
关键词
D O I
10.1016/0002-9610(79)90163-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
A case of massive air embolus secondary to use of an intravenous infusion pump is presented. The pump is unable to detect air entering the intravenous line if the air enters distal to the air detection device. A simple solution is presented. © 1979.