ONLINE IMMUNOAFFINITY SAMPLE PRETREATMENT FOR COLUMN LIQUID-CHROMATOGRAPHY - EVALUATION OF DESORPTION TECHNIQUES AND OPERATING-CONDITIONS USING AN ANTIESTROGEN IMMUNO-PRECOLUMN AS A MODEL SYSTEM

被引:30
作者
FARJAM, A [1 ]
BRUGMAN, AE [1 ]
LINGEMAN, H [1 ]
THBRINKMAN, UA [1 ]
机构
[1] FREE UNIV AMSTERDAM,DEPT ANALYT CHEM,DE BOELELAAN 1083,1081 HV AMSTERDAM,NETHERLANDS
关键词
IMMUNOAFFINITY PRECOLUMN; COLUMN SWITCHING; COLUMN LIQUID CHROMATOGRAPHY; ESTROGEN; URINE AND PLASMA SAMPLES;
D O I
10.1039/an9911600891
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunoaffinity precolumn (immuno-precolumn) containing an immobilized antibody directed against estrogen steroids, was used as a model system for the evaluation of different desorbing techniques, suitable for on-line coupling to column liquid chromatography (LC). Desorption of estrogen analytes from the immuno-precolumn proved to be impossible with the buffers and chaotropic solutions frequently used in affinity desorption. Micellar solutions are effective in obstructing the antibody-antigen reaction, but their use as desorbing solutions was not found to be practical because of the large interferences introduced into the chromatograms. Desorption with aqueous solutions at elevated temperature, created by microwave action or conventional heating, although effective is not practical in this instance, because the agarose used in this study as the stationary phase for the immuno-precolumn is prone to heat decomposition. The most effective and practical approach is desorption with a methanol-water mixture (95 + 5 v/v). On-line dilution of the eluate allows the concentration of the desorbed analytes using a reversed-phase LC system with subsequent separation and ultraviolet detection. The performance of the system with spiked urine and plasma samples, which were introduced directly into the system, was evaluated and the results were compared with immunoselective desorption.
引用
收藏
页码:891 / 896
页数:6
相关论文
共 15 条
[1]  
[Anonymous], 1989, REC BIOCH M
[2]  
Davis G. C., 1985, Plant growth substances 1985. Proceedings of the 12th international conference on plant growth substances held at Heidelberg, August 26-31, 1985, P44
[3]   IMMUNOAFFINITY PRE-COLUMN FOR SELECTIVE ONLINE SAMPLE PRE-TREATMENT IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY DETERMINATION OF 19-NORTESTOSTERONE [J].
FARJAM, A ;
DEJONG, GJ ;
FREI, RW ;
BRINKMAN, UAT ;
HAASNOOT, W ;
HAMERS, ARM ;
SCHILT, R ;
HUF, FA .
JOURNAL OF CHROMATOGRAPHY, 1988, 452 :419-433
[4]   IMMUNOAFFINITY PRECOLUMN FOR SELECTIVE SAMPLE PRETREATMENT IN COLUMN LIQUID-CHROMATOGRAPHY - IMMUNOSELECTIVE DESORPTION [J].
FARJAM, A ;
BRUGMAN, AE ;
SOLDAAT, A ;
TIMMERMAN, P ;
LINGEMAN, H ;
DEJONG, GJ ;
FREI, RW ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1991, 31 (9-10) :469-477
[5]  
FARJAM A, IN PRESS INT J ENV A
[6]   INSOLUBLE ANTIBODY COLUMN FOR ISOLATION AND QUANTITATIVE-DETERMINATION OF GIBBERELLINS [J].
FUCHS, Y ;
GERTMAN, E .
PLANT AND CELL PHYSIOLOGY, 1974, 15 (04) :629-633
[7]   DETERMINATION OF BETA-19-NORTESTOSTERONE AND ITS METABOLITE ALPHA-19-NORTESTOSTERONE IN BIOLOGICAL SAMPLES AT THE SUB PARTS PER BILLION LEVEL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE IMMUNOAFFINITY SAMPLE PRETREATMENT [J].
HAASNOOT, W ;
SCHILT, R ;
HAMERS, ARM ;
HUF, FA ;
FARJAM, A ;
FREI, RW ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (01) :157-171
[8]   IMMUNOLOGICAL-CHROMATOGRAPHIC ANALYSIS OF LYSOZYME VARIANTS [J].
JANIS, LJ ;
GROTT, A ;
REGNIER, FE ;
SMITHGILL, SJ .
JOURNAL OF CHROMATOGRAPHY, 1989, 476 :235-244
[9]   IMMUNOLOGICAL-CHROMATOGRAPHIC ANALYSIS [J].
JANIS, LJ ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1988, 444 :1-11
[10]   SIMPLIFIED QUANTITATIVE-DETERMINATION OF PLASMA PHENYTOIN - ONLINE PRECOLUMN HIGH-PERFORMANCE LIQUID IMMUNOAFFINITY CHROMATOGRAPHY WITH SAMPLE PRE-PURIFICATION [J].
JOHANSSON, B .
JOURNAL OF CHROMATOGRAPHY, 1986, 381 (01) :107-113