COMPARATIVE MEASUREMENTS OF BONE-MARROW DOSE IN QUANTITATIVE COMPUTED-TOMOGRAPHY (QCT), DUAL PHOTON X-RAY (DPX) AND CONVENTIONAL LUMBAR SPINE X-RAY

被引:4
作者
KASPERCZYK, A
FREYSCHMIDT, J
WELL, JC
SEEGER, W
机构
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1991年 / 155卷 / 02期
关键词
BONE DENSITY MEASUREMENT; BONE MARROW DOSE; QCT; DPX;
D O I
10.1055/s-2008-1033237
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One of the issues in the discussion on the best method for measuring the bone mineral content is the relevance of the applied dose. We used highly sensitive thermoluminescent dosimeters (TLD) to directly compare bone marrow doses in a human phantom. DPX gave a bone marrow dose in the lumbar spine of 4-mu-Gy, in QCT the dose corrected to the same amount of irradiated marrow was about 1 mGy. This value is in the same range as conentional a.p. plus lateral view x-rays of the lumbar spine. Corrected to the total body dose, the QCT dose is as low as 10% of the yearly background irradiation. It should therefore be radiobiologically irrelevant.
引用
收藏
页码:155 / 158
页数:4
相关论文
共 19 条
[1]   MODIFIED METHOD OF SPINAL COMPUTED-TOMOGRAPHY FOR TRABECULAR BONE-MINERAL MEASUREMENTS [J].
BANKS, LM ;
STEVENSON, JC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (03) :463-467
[2]   QUANTITATIVE CT FOR DETERMINATION OF BONE-MINERAL DENSITY - A REVIEW [J].
CANN, CE .
RADIOLOGY, 1988, 166 (02) :509-522
[3]   LOW-DOSE CT SCANNING FOR QUANTITATIVE SPINAL MINERAL ANALYSIS [J].
CANN, CE .
RADIOLOGY, 1981, 140 (03) :813-815
[4]   X-RAY-INDUCED BREAKAGE AND REJOINING OF HUMAN INTERPHASE CHROMOSOMES [J].
CORNFORTH, MN ;
BEDFORD, JS .
SCIENCE, 1983, 222 (4628) :1141-1143
[5]  
EHLING UH, 1987, STRAHLENTHER ONKOL, V163, P283
[6]   2 POSTPROCESSING CT TECHNIQUES FOR DETERMINING THE COMPOSITION OF TRABECULAR BONE [J].
GOODSITT, MM ;
ROSENTHAL, DI ;
REINUS, WR ;
COUMAS, J .
INVESTIGATIVE RADIOLOGY, 1987, 22 (03) :209-215
[7]   EVIDENCE FOR LINEAR RESPONSE FOR THE INDUCTION OF MUTATIONS IN HUMAN-CELLS BY X-RAY-EXPOSURES BELOW 10 RADS [J].
GROSOVSKY, AJ ;
LITTLE, JB .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1985, 82 (07) :2092-2095
[8]   DIAGNOSTIC NOTES - LUMBAR BMC REPRODUCIBILITY AS EVALUATED BY MEANS OF DUAL PHOTON-ABSORPTIOMETRY [J].
ISAIA, G ;
MUSSETTA, M ;
SALAMANO, G ;
CARLEVATTO, V ;
MOLINATTI, GM .
MATURITAS, 1988, 10 (01) :59-63
[9]  
KEREIAKES JG, 1980, HDB RAD DOSES NUCL M, P241
[10]  
LAUBENBERGER T, 1990, DT ARZTEVERLAG, P620