CORRECTION FOR DISTORTION IN A BEAM OUTLINE TRANSFER DEVICE IN RADIOTHERAPY CT-BASED SIMULATION

被引:7
作者
RAGAN, DP
HE, TM
LIU, XL
机构
[1] Wayne State University, School of Medicine, Radiation Oncology Department, Detroit, Michigan 48201
关键词
3-D CT-BASED SIMULATION; 3-D TREATMENT PLANNING;
D O I
10.1118/1.597082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In using a CT scanner as a radiation therapy simulator, it would be helpful to be able to transfer the beam outline from the computer plan to the patient's skin. A beam outline transfer device has been constructed and installed on a Siemens' DRH CT scanner gantry. The planned treatment beam geometry from a 3-D computerized simulation and planning system can be projected onto the patient's skin surface accurately and efficiently. The positioning accuracy achieved is within +/- 0.1 cm over a 20 cm X 20 cm field. Integrating the device in to the CT scanner, simplifies the device and reduces the cost over an externally mounted device. Two unsuccessful methods to correct the projection distortions are also mentioned In order to achieve the reported beam outline transfer accuracy, a system based on our empirically derived calibration procedure is described.
引用
收藏
页码:179 / 185
页数:7
相关论文
共 10 条
[1]  
FOLEY JD, 1984, FUNDAMENTALS INTERAC, P255
[2]  
FRAASS BA, 1990, COMP MED PHYS, V17, P303
[3]   AN OPTICAL SCANNER AS AN AID IN SIMULATING TREATMENT WITH CT DATA [J].
GOITEIN, M ;
MENTO, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (06) :1201-1204
[4]   MULTIDIMENSIONAL TREATMENT PLANNING .2. BEAM EYE-VIEW, BACK PROJECTION, AND PROJECTION THROUGH CT SECTIONS [J].
GOITEIN, M ;
ABRAMS, M ;
ROWELL, D ;
POLLARI, H ;
WILES, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (06) :789-797
[5]  
LIU XL, 1989, P SOC PHOTO-OPT INS, V1153, P350
[6]   CT SIMULATOR - A NEW 3-D PLANNING AND SIMULATING SYSTEM FOR RADIOTHERAPY .1. DESCRIPTION OF SYSTEM [J].
NISHIDAI, T ;
NAGATA, Y ;
TAKAHASHI, M ;
ABE, M ;
YAMAOKA, N ;
ISHIHARA, H ;
KUBO, Y ;
OHTA, H ;
KAZUSA, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03) :499-504
[7]   VIRTUAL SIMULATION - INITIAL CLINICAL-RESULTS [J].
ROSENMAN, J ;
SAILER, SL ;
SHEROUSE, GW ;
CHANEY, EL ;
TEPPER, JE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (04) :843-851
[8]   VIRTUAL SIMULATION IN THE CLINICAL SETTING - SOME PRACTICAL CONSIDERATIONS [J].
SHEROUSE, GW ;
BOURLAND, JD ;
REYNOLDS, K ;
MCMURRY, HL ;
MITCHELL, TP ;
CHANEY, EL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 19 (04) :1059-1065
[9]   THE PORTABLE VIRTUAL SIMULATOR [J].
SHEROUSE, GW ;
CHANEY, EL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (02) :475-482
[10]  
SHEROUSE GW, 1989, COMMUNICATION