POROUS GRAPHITIZED CARBON AND OCTADECYLSILICA COLUMNS IN THE SEPARATION OF SOME MONOAMINE-OXIDASE INHIBITORY DRUGS

被引:13
作者
FORGACS, E [1 ]
VALKO, K [1 ]
CSERHATI, T [1 ]
MAGYAR, K [1 ]
机构
[1] SEMMELWEIS UNIV MED,DEPT PHARMACOL,H-1085 BUDAPEST 8,HUNGARY
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 631卷 / 1-2期
关键词
D O I
10.1016/0021-9673(93)80523-B
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The retentions of seventeen monoamine oxidase inhibitory drugs (propargylamine derivatives) were determined on a porous graphitized carbon (PGC) column using unbuffered methanol-water and acetonitrile-water eluents and on an octadecylsilica column with methanol-water eluents using constant and varying buffer concentrations. Principal component analysis showed that the retention characteristics of the PGC and octadecylsilica columns differ considerably. A marked deviation between the selectivities of methanol and acetonitrile organic modifiers was observed on PGC. The buffer concentration has a significant impact on the retention of drugs on the octadecylsilica column. The type of substitution (heterocyclic, condensed ring, substituted benzene) accounts for the retention differences irrespective of the type of column, eluent and buffer concentration.
引用
收藏
页码:207 / 213
页数:7
相关论文
共 23 条
[1]   SILICA-GEL AND CARBON COLUMN PACKINGS FOR USE IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BEREK, D ;
NOVAK, I .
CHROMATOGRAPHIA, 1990, 30 (9-10) :582-590
[2]  
BERRIDGE JC, 1988, J CHROMATOGR, V449, P317, DOI 10.1016/S0021-9673(00)94391-7
[3]   SILICA - BACKBONE MATERIAL OF LIQUID-CHROMATOGRAPHIC COLUMN PACKINGS [J].
BERTHOD, A .
JOURNAL OF CHROMATOGRAPHY, 1991, 549 (1-2) :1-28
[4]   EFFECT OF NATURE OF SUPPORT AND IMPREGNATING AGENT ON LIPOPHILICITY DETERMINATION FOR NONIONIC SURFACTANTS BY REVERSED-PHASE THIN-LAYER CHROMATOGRAPHY [J].
CSERHATI, T ;
ILLES, Z .
CHROMATOGRAPHIA, 1991, 31 (3-4) :152-156
[5]   ANOMALOUS RETENTION BEHAVIOR OF SOME SYNTHETIC NUCLEOSIDES ON ALUMINUM-OXIDE LAYERS [J].
CSERHATI, T .
JOURNAL OF CHROMATOGRAPHY, 1991, 543 (02) :425-438
[6]   POROUS GLASSY-CARBON, A NEW COLUMNS PACKING MATERIAL FOR GAS-CHROMATOGRAPHY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GILBERT, MT ;
KNOX, JH ;
KAUR, B .
CHROMATOGRAPHIA, 1982, 16 :138-148
[7]  
HAGGERTY WJ, 1974, RES DEV, V25, P30
[8]   SOLVOPHOBIC INTERACTIONS IN LIQUID-CHROMATOGRAPHY WITH NONPOLAR STATIONARY PHASES [J].
HORVATH, C ;
MELANDER, W ;
MOLNAR, I .
JOURNAL OF CHROMATOGRAPHY, 1976, 125 (01) :129-156
[9]  
KALISZAN R, 1990, J CHROMATOGR, V333, P499
[10]  
KAUR B, 1990, LC GC, V3, P41