STUDY OF SEMITRANSPARENT PALLADIUM CONTACTS ON MERCURIC IODIDE BY PHOTOLUMINESCENCE SPECTROSCOPY AND THERMALLY STIMULATED CURRENT MEASUREMENTS

被引:11
作者
BAO, XJ
SCHLESINGER, TE
JAMES, RB
GENTRY, GL
CHENG, AY
ORTALE, C
机构
[1] SANDIA NATL LABS,DIV ADV MAT RES,LIVERMORE,CA 94550
[2] EG&G ENERGY MEASUREMENTS INC,GOLETA,CA 93116
关键词
D O I
10.1063/1.348396
中图分类号
O59 [应用物理学];
学科分类号
摘要
Semitransparent palladium contacts on mercuric iodide were studied by low temperature photoluminescence spectroscopy and thermally stimulated conductivity. These contacts were deposited either by thermal evaporation or by plasma sputtering. Changes due to palladium deposition were found in the photoluminescence spectra and were attributed to modifications in the stoichiometry within the palladium/mercuric iodide interfacial region. Thermally stimulated conductivity measurements revealed two dominant traps with activation energies of 0.010 and 0.54 eV. The importance of these traps in the application of nuclear detection is discussed.
引用
收藏
页码:4247 / 4252
页数:6
相关论文
共 35 条
  • [1] AKOPYAN IK, 1987, FIZ TVERD TELA, V29, P238
  • [2] WHAT CAN BE EXPECTED FROM HIGH-Z SEMICONDUCTOR-DETECTORS
    ARMANTROUT, GA
    SWIERKOWSKI, SP
    SHEROHMAN, JW
    YEE, JH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 121 - 125
  • [3] BAO XH, UNPUB
  • [4] HIGH-RESOLUTION 4.2 K NEAR BAND-GAP PHOTOLUMINESCENCE SPECTRUM OF MERCURIC IODIDE
    BAO, XJ
    SCHLESINGER, TE
    JAMES, RB
    ORTALE, C
    VANDENBERG, L
    [J]. JOURNAL OF APPLIED PHYSICS, 1990, 68 (06) : 2951 - 2954
  • [5] INVESTIGATION OF COPPER ELECTRODES FOR MERCURIC IODIDE DETECTOR APPLICATIONS
    BAO, XJ
    SCHLESINGER, TE
    JAMES, RB
    STULEN, RH
    ORTALE, C
    VANDENBERG, L
    [J]. JOURNAL OF APPLIED PHYSICS, 1990, 67 (12) : 7265 - 7267
  • [6] INCORPORATION OF DEFECTS DURING PROCESSING OF MERCURIC IODIDE DETECTORS
    BAO, XJ
    SCHLESINGER, TE
    JAMES, RB
    STULEN, RH
    ORTALE, C
    CHENG, AY
    [J]. JOURNAL OF APPLIED PHYSICS, 1990, 68 (01) : 86 - 92
  • [7] BLASI CD, 1978, NUCL INSTRUM METHODS, V150, P103
  • [8] OPTO-ELECTRONIC PROPERTIES OF MERCURIC IODIDE
    BUBE, RH
    [J]. PHYSICAL REVIEW, 1957, 106 (04): : 703 - 717
  • [9] RUTHERFORD BACKSCATTERING AND AUGER-SPECTROSCOPY OF MERCURIC IODIDE DETECTORS
    FELTER, TE
    STULEN, RH
    SCHNEPPLE, WF
    ORTALE, C
    VANDENBERG, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (02) : 195 - 198
  • [10] STUDY OF IMPERFECTIONS IN MERCURY IODIDE BY THERMALLY STIMULATED CURRENTS METHOD
    GELBART, U
    YACOBY, Y
    BEINGLASS, I
    HOLZER, A
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 135 - 141