SCREENING FOR IRON-DEFICIENCY - AN ANALYSIS BASED ON BONE-MARROW EXAMINATIONS AND SERUM FERRITIN DETERMINATIONS IN A POPULATION-SAMPLE OF WOMEN

被引:190
作者
HALLBERG, L
BENGTSSON, C
LAPIDUS, L
LINDSTEDT, G
LUNDBERG, PA
HULTEN, L
机构
[1] GOTHENBURG UNIV, SAHLGRENKA HOSP, DEPT PRIMARY HLTH CARE, S-41124 GOTHENBURG, SWEDEN
[2] GOTHENBURG UNIV, SAHLGRENKA HOSP, DEPT CLIN CHEM, S-41124 GOTHENBURG, SWEDEN
[3] GOTHENBURG UNIV, SAHLGRENKA HOSP, DEPT CLIN NUTR, S-41124 GOTHENBURG, SWEDEN
关键词
D O I
10.1111/j.1365-2141.1993.tb03225.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Efficacy of different methods in screening for iron deficiency was re-examined in a randomly selected sample of 38-year-old women (n = 203) with known iron status based on absence/presence of stainable iron in bone-marrow smears. The study was made in 1968-69. Serum ferritin (SF) was determined in 1978 in frozen sera using the Ramco IRMA and, in 1992, samples were re-analysed using a RIA calibrated with the International Standard 80/602 for SF determination. The effect of storage on SF was calculated from a previously established relationship (courtesy of Dr Mark Worwood. Cardiff) between the results obtained with the Ramco assay and assays calibrated with IS 80/602. The distributions in iron replete and iron deficient women showed less overlap (diagnostic efficiency 91%) for SF than for other haematological parameters. The best discrimination was obtained at SF < 16 mug/l (specificity 98%: sensitivity 75%). Absence of iron stores was associated with signs of an iron deficient erythropoiesis. starting already at SF 25-40 mug/l. Use of multiple criteria to diagnose iron deficiency falsely reduces prevalence figures for iron deficiency.
引用
收藏
页码:787 / 798
页数:12
相关论文
共 37 条
  • [1] IMMUNORADIOMETRIC ASSAY FOR FERRITIN IN SERUM OF NORMAL SUBJECTS AND PATIENTS WITH IRON-DEFICIENCY AND IRON OVERLOAD
    ADDISON, GM
    BEAMISH, MR
    JACOBS, A
    HALES, CN
    HODGKINS, M
    LLEWELLIN, P
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1972, 25 (04) : 326 - +
  • [2] [Anonymous], 1984, ASSESSMENT IRON NUTR
  • [3] MEASUREMENT OF FERRITIN IN SERUM BY RADIOIMMUNOASSAY
    BARNETT, MD
    GORDON, YB
    AMESS, JAL
    MOLLIN, DL
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1978, 31 (08) : 742 - 748
  • [4] BENGTSSON C, 1973, ACTA MED SCAND, P311
  • [5] Chambers J. M., 1983, GRAPHICAL METHODS DA
  • [6] ASSESSING IRON STATUS OF A POPULATION
    COOK, JD
    FINCH, CA
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1979, 32 (10) : 2115 - 2119
  • [7] COOK JD, 1986, BLOOD, V68, P726
  • [8] COOK JD, 1976, BLOOD, V48, P449
  • [9] SERUM FERRITIN AS A MEASURE OF IRON STORES IN NORMAL SUBJECTS
    COOK, JD
    LIPSCHIT.DA
    MILES, LEM
    FINCH, CA
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1974, 27 (07) : 681 - 687
  • [10] PREVALENCE AND CAUSES OF ANEMIA IN THE UNITED-STATES, 1976 TO 1980
    DALLMAN, PR
    YIP, R
    JOHNSON, C
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1984, 39 (03) : 437 - 445