TRANSRECTAL SONOGRAPHIC CYSTOURETHROGRAPHY - STUDIES IN STRESS URINARY-INCONTINENCE
被引:14
作者:
CHANG, HC
CHANG, SC
KUO, HC
TSAI, TC
机构:
[1] NATL TAIWAN UNIV,COLL MED,DEPT UROL,TAIPEI,TAIWAN
[2] BUDDHIST TZU CHI GEN HOSP,DEPT UROL,TAIPEI,TAIWAN
来源:
关键词:
D O I:
10.1016/0090-4295(90)80183-N
中图分类号:
R5 [内科学];
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号:
1002 ;
100201 ;
摘要:
Transrectal ultrasonic sagittal transducer is an excellent modality to image the bladderand urethra in dynamic change, In female patients, we found it is also helpful for the diagnosis of urinary stress incontinence. The posterior urethrovesical (PUV) angle is measured with the transrectal sonoprobe under strain and non-strain conditions. We compared the results of sonographic cystourethrogram with the radiographic chain cystourethrogram. The sonographic cystourethrography is superior to the radiograph, The former may estimate the PUV angle accurately and differentiate between the patients with and without stress urinary incontinence. Furthermore, we also use the transrectal sagittal probe intraoperatively to adjust the suspension force as well as PUV angle in patients who underwent vesical neck suspension for stress urinary incontinence (SUI). © 1990 Cahners Publishing Company.
引用
收藏
页码:488 / 492
页数:5