NO CORRELATION BETWEEN QUANTITATIVE ELECTROENCEPHALOGRAPHIC MEASUREMENTS AND MOVEMENT RESPONSE TO NOXIOUS STIMULI DURING ISOFLURANE ANESTHESIA IN RATS

被引:122
作者
RAMPIL, IJ
LASTER, MJ
机构
[1] Department of Anesthesia, University of California, San Francisco
关键词
ANESTHETICS; VOLATILE; ISOFLURANE; ELECTROENCEPHALOGRAPHY; BURST SUPPRESSION; MONITORING; DEPTH OF ANESTHESIA; POTENCY; MAC(ED(50));
D O I
10.1097/00000542-199211000-00014
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A meaningful use of the electroencephalogram (EEG) for monitoring depth of anesthesia has proven elusive. Although changes in the EEG with changing anesthetic dose or concentration have been noted for 60 yr, it has been difficult to demonstrate reliable, quantitative correlation between the EEG and other physiologic measures of anesthetic depth. We attempted to correlate several quantitative EEG measurements in rats, including average amplitude, spectral edge frequency, and burst suppression ratio, with the movement response to supramaximal noxious stimulation. We anesthetized 21 Sprague-Dawley rats with isoflurane 1.5% and allowed them to breathe spontaneously. After equilibration, EEG was recorded for off-line analysis; then a noxious stimulation was delivered with a tail clamp and the somatic response noted. Isoflurane concentration was adjusted up and down. and the EEG and movement response to tail clamp were assessed at each level until the minimum alveolar concentration was determined in each rat. We found no EEG dose response to increasing inspired concentrations of isoflurane, except for an increasing degree of burst suppression. We found no difference in any parameter between rats that responded and those that did not respond to stimuli at a given concentration of isoflurane. Finally, we found that the presence of burst suppression did not predict lack of response.
引用
收藏
页码:920 / 925
页数:6
相关论文
共 28 条
[1]   NEUROPHYSIOLOGIC EFFECTS OF GENERAL ANESTHETICS .1. ELECTROENCEPHALOGRAM AND SENSORY EVOKED-RESPONSES IN MAN [J].
CLARK, DL ;
ROSNER, BS .
ANESTHESIOLOGY, 1973, 38 (06) :564-582
[2]   NERVE IMPULSE CONDUCTION AND CUTANEOUS RECEPTOR RESPONSES DURING GENERAL ANESTHESIA [J].
DEJONG, RH ;
NACE, RA .
ANESTHESIOLOGY, 1967, 28 (05) :851-&
[3]   The effects of anesthetics on action potentials in the cerebral cortex of the cat [J].
Derbyshire, AJ ;
Rempel, B ;
Forbes, A ;
Lambert, EF .
AMERICAN JOURNAL OF PHYSIOLOGY, 1936, 116 (03) :577-596
[4]  
DONEGAN JH, 1990, MONITORING ANESTHESI, P431
[5]   A COMPARISON OF MEDIAN FREQUENCY, SPECTRAL EDGE FREQUENCY, A FREQUENCY BAND POWER RATIO, TOTAL POWER, AND DOMINANCE SHIFT IN THE DETERMINATION OF DEPTH OF ANESTHESIA [J].
DRUMMOND, JC ;
BRANN, CA ;
PERKINS, DE ;
WOLFE, DE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1991, 35 (08) :693-699
[6]  
DWYER R, 1991, ANESTHESIOLOGY, V75, pA1025
[7]   ELECTROENCEPHALOGRAM IN MAN ANESTHETIZED WITH FORANE [J].
EGER, EI ;
STEVENS, WC ;
CROMWELL, TH .
ANESTHESIOLOGY, 1971, 35 (05) :504-&
[8]  
GHALY R, 1991, ANESTHESIOLOGY, V75, pA613
[10]  
LOSASSO TJ, 1991, ANESTHESIOLOGY, V75, pA1032