COLOR FLOW ULTRASOUND FOR DELINEATING MICROSURGICAL VESSELS - A CLINICAL AND EXPERIMENTAL-STUDY

被引:41
作者
AMERHAUSER, A
MOELLEKEN, BRW
MATHES, SJ
GOODING, G
GOLDSTEIN, R
CALLEN, P
FILLY, RA
MAY, JW
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT SURG,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,DIV PLAST RECONSTRUCT & HAND SURG,SAN FRANCISCO,CA 94143
[3] MASSACHUSETTS GEN HOSP,BOSTON,MA 02114
关键词
D O I
10.1097/00000637-199303000-00001
中图分类号
R61 [外科手术学];
学科分类号
摘要
There is a need in plastic and reconstructive surgery for a method of monitoring flaps and replants pre- and postoperatively. This study evaluates color flow Doppler done as a monitoring technique for microvascular vessels. The capability of color flow ultrasound to monitor venous and arterial insufficiency and occlusion was studied by means of an experimental system in the Yucatan miniature swine model. A circulatory circuit in line with a magnetic flow probe is created. Measurements are made on the isolated hind limb of the animal. Color flow ultrasound is demonstrated to be a technique that is sensitive to venous and arterial insufficiency at flow rates as low as 3.0 ml/min. Characteristic waveform patterns are shown to predict arterial and venous insufficiency before they actually progress to occlusion. A clinical series of 25 postoperative patients is presented, consisting of volunteer studies as well as pre- and postoperative examinations of free flaps and replantations. Color flow ultrasound is shown to visualize a spectrum of pre- and postoperative microvascular conduits encountered in plastic and reconstructive surgery.
引用
收藏
页码:193 / 203
页数:11
相关论文
共 24 条
[1]  
BANDYK DF, 1990, SURG CLIN N AM, V70, P71
[2]   HEMODYNAMICS OF VEIN GRAFT STENOSIS [J].
BANDYK, DF ;
SEABROOK, GR ;
MOLDENHAUER, P ;
LAVIN, J ;
EDWARDS, J ;
CATO, R ;
TOWNE, JB .
JOURNAL OF VASCULAR SURGERY, 1988, 8 (06) :688-695
[3]  
CAMPBELL S, 1983, LANCET, V1, P675
[4]   EFFECTS OF PERFUSION OF VARIOUS SOLUTIONS ON NO-REFLOW PHENOMENON IN EXPERIMENTAL FREE FLAPS [J].
CHAIT, LA ;
MAY, JW ;
OBRIEN, BM ;
HURLEY, JV .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1978, 61 (03) :421-430
[5]   DEEP VENOUS THROMBOSIS - US ASSESSMENT USING VEIN COMPRESSION [J].
CRONAN, JJ ;
DORFMAN, GS ;
SCOLA, FH ;
SCHEPPS, B ;
ALEXANDER, J .
RADIOLOGY, 1987, 162 (01) :191-194
[6]   UTERINE ARTERY DOPPLER VELOCIMETRY IN PREGNANT-WOMEN WITH HYPERTENSION [J].
FLEISCHER, A ;
SCHULMAN, H ;
FARMAKIDES, G ;
BRACERO, L ;
GRUNFELD, L ;
ROCHELSON, B ;
KOENIGSBERG, M .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1986, 154 (04) :806-813
[7]  
LOH C L, 1978, Ultrasound in Medicine and Biology, V4, P37, DOI 10.1016/0301-5629(78)90005-4
[8]   REMOVABLE THERMOCOUPLE PROBE MICROVASCULAR PATENCY MONITOR - AN EXPERIMENTAL AND CLINICAL-STUDY [J].
MAY, JW ;
LUKASH, FN ;
GALLICO, GG ;
STIRRAT, CR .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1983, 72 (03) :366-379
[9]   NO-REFLOW PHENOMENON IN EXPERIMENTAL FREE FLAPS [J].
MAY, JW ;
CHAIT, LA ;
OBRIEN, BM ;
HURLEY, JV .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1978, 61 (02) :256-267
[10]   DOPPLER COLOR FLOW IMAGING [J].
MERRITT, CRB .
JOURNAL OF CLINICAL ULTRASOUND, 1987, 15 (09) :591-&