DIRECT MEASUREMENT OF PULMONARY MICROVASCULAR DISTENSIBILITY

被引:24
作者
HILLIER, SC
GODBEY, PS
HANGER, CC
GRAHAM, JA
PRESSON, RG
OKADA, O
LINEHAN, JH
DAWSON, CA
WAGNER, WW
机构
[1] INDIANA UNIV, SCH MED, DEPT ANESTHESIA, INDIANAPOLIS, IN 46202 USA
[2] INDIANA UNIV, SCH MED, DEPT PHYSIOL BIOPHYS, INDIANAPOLIS, IN 46202 USA
[3] INDIANA UNIV, SCH MED, DEPT PEDIAT, INDIANAPOLIS, IN 46202 USA
[4] MED COLL WISCONSIN, DEPT PHYSIOL, MILWAUKEE, WI 53226 USA
[5] CLEMENT J ZEBLOCKI VET ADM CTR, RES SERV, MILWAUKEE, WI 53233 USA
关键词
PULMONARY CIRCULATION; PULMONARY VASCULAR DISTENSIBILITY; PULMONARY MICROCIRCULATION; ARTERIOLES; VENULES; VIDEOMICROSCOPY; DOGS;
D O I
10.1152/jappl.1993.75.5.2106
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Pulmonary vascular distensibility has an important influence on pulmonary hemodynamics. Although many measurements of distensibility have been made on large pulmonary vessels, there is less information on microvascular distensibility. We have measured the distensibility of the smallest (<70-mum-diam) precapillary arterioles and postcapillary venules. Isolated dog lobes, at 2.5 cmH2O transpulmonary pressure, were perfused at low flows, which caused the arteriovenous pressure gradient to be very small and thereby permitted accurate estimation of microvascular pressure. As microvascular pressure was systematically varied between 0 and 30 mmHg, subpleural microvascular diameters were determined from computer-enhanced images obtained by videomicroscopy. Arteriolar and venular distensibilities were not different from each other. The microvascular pressure-diameter relationship was alinear with distensibility coefficients of 1-3% mmHg-1, values that are of the same order of magnitude as previously measured distensibilities of 100- to 1,000-mum-diam canine pulmonary vessels.
引用
收藏
页码:2106 / 2111
页数:6
相关论文
共 25 条
[1]   DISTENSIBILITY OF SMALL VEINS OF THE DOG LUNG [J].
ALTINAWI, A ;
CLOUGH, AV ;
HARDER, DR ;
LINEHAN, JH ;
RICKABY, DA ;
DAWSON, CA .
JOURNAL OF APPLIED PHYSIOLOGY, 1992, 73 (05) :2158-2165
[2]   DISTENSIBILITY OF SMALL ARTERIES OF THE DOG LUNG [J].
ALTINAWI, A ;
MADDEN, JA ;
DAWSON, CA ;
LINEHAN, JH ;
HARDER, DR ;
RICKABY, DA .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (05) :1717-1722
[3]   ADAPTATION OF VASCULAR PRESSURE-FLOW-VOLUME HYSTERESIS IN ISOLATED RABBIT LUNGS [J].
BECK, KC ;
HILDEBRANDT, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 54 (03) :671-679
[4]   Pathology of the vessels of the pulmonary circulation - Part I [J].
Brenner, O .
ARCHIVES OF INTERNAL MEDICINE, 1935, 56 (02) :211-237
[5]   EXTENSIBILITY OF BLOOD VESSELS IN ISOLATED RABBIT LUNGS [J].
CARO, CG ;
SAFFMAN, PG .
JOURNAL OF PHYSIOLOGY-LONDON, 1965, 178 (02) :193-&
[6]   HEMODYNAMIC RESPONSES OF ISOLATED CAT LUNGS DURING FORWARD AND RETROGRADE PERFUSION [J].
DAWSON, CA ;
JONES, RL ;
HAMILTON, LH .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 35 (01) :95-102
[7]   PATENCY AND COMPLIANCE OF PULMONARY VEINS WHEN AIRWAY PRESSURE EXCEEDS BLOOD-PRESSURE [J].
FUNG, YC ;
SOBIN, SS ;
TREMER, H ;
YEN, MRT ;
HO, HH .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 54 (06) :1538-1549
[8]   SITE OF RECRUITMENT IN THE PULMONARY MICROCIRCULATION [J].
HANSON, WL ;
EMHARDT, JD ;
BARTEK, JP ;
LATHAM, LP ;
CHECKLEY, LL ;
CAPEN, RL ;
WAGNER, WW .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 66 (05) :2079-2083
[9]   A HEMODYNAMIC MODEL REPRESENTATION OF THE DOG LUNG [J].
HAWORTH, ST ;
LINEHAN, JH ;
BRONIKOWSKI, TA ;
DAWSON, CA .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (01) :15-26
[10]  
HORSFIELD K, 1989, RESP PHYSL ANAL APPR, V40, P499