LIQUID-CHROMATOGRAPHIC DETERMINATION OF THE PLASTICIZER DI(2-ETHYLHEXYL) PHTHALATE (DEHP) IN PVC PLASTICS

被引:11
作者
FUNG, YS
TANG, ASK
机构
[1] Department of Chemistry, University of Hong Kong
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1994年 / 350卷 / 12期
关键词
D O I
10.1007/BF00323673
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, simple and reliable method for the analysis of DEHP in PVC products was developed using a one-step Soxhlet extraction prior to HPLC determination. The linear range from 1.25 mu/g to 250 mg/g of DEHP in PVC was found sufficient to cover the normal concentrations encountered. The reliability of the method was established by comparison with the ASTM method and no potential interferent was identified except a large concentration of DIMP.
引用
收藏
页码:721 / 723
页数:3
相关论文
共 6 条
[1]  
GRIESEMER RA, 1985, CHRONIC HAZARD ADVIS, P1
[2]  
HARNETT DL, 1975, INTRO STATISTICAL ME, P295
[3]  
KRAXNER M, 1986, S BIOL HUNG, V31, P559
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE SIMULTANEOUS SEPARATION AND DETERMINATION OF 3 ADDITIVES IN POLYVINYL-CHLORIDE) [J].
SREENIVASAN, K .
JOURNAL OF CHROMATOGRAPHY, 1986, 357 (03) :433-435
[5]  
1975, D3421 AM SOC TEST MA
[6]  
1988, VOLUNTARY STANDARD S, P1