CHARACTERISTICS OF TRANSITION BOILING IN SODIUM-HEATED STEAM-GENERATOR TUBES

被引:17
作者
FRANCE, DM
CARLSON, RD
CHIANG, T
PRIEMER, R
机构
[1] Argonne National Laboratory, Components Technology Division, Argonne, IL
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 1979年 / 101卷 / 02期
关键词
D O I
10.1115/1.3450959
中图分类号
O414.1 [热力学];
学科分类号
摘要
Thermal fluctuations were measured in the tube wall in the transition boiling zone of a full-scale LMFBR sodium-heated steam generator tube. The tube had an inside diameter = 10 mm, wall thickness = 2.90 mm, heated length = 13.1 m, and material = 21/4 Cr-1 Mo steel. Water flowed vertically upwards inside the straight tube, and sodium flowed counter-currently in a surrounding annulus. Results of thermal, spectral, and thermal stress analyses are presented for a test within the normal operating range of LMFBR steam generators. Results of other tests are presented that show the effects and sensitivity of sodium temperature and water pressure on the severity of the thermal fluctuations. © 1979 by ASME.
引用
收藏
页码:270 / 275
页数:6
相关论文
共 12 条
[1]  
BAILEY NA, 1970, AEEWM1000
[2]   CALCULATION OF TUBE DEGRADATION INDUCED BY DRYOUT INSTABILITY IN SODIUM-HEATED STEAM-GENERATORS [J].
CHIANG, T ;
FRANCE, DM ;
BUMP, TR .
NUCLEAR ENGINEERING AND DESIGN, 1977, 41 (02) :181-191
[3]  
CHU CL, 1977, 77WANE5 ASME PAP
[4]  
CHU CL, 1976, ASME76JPGCNE2 PAP
[5]  
DEMUNK PJ, 1975, INT ATOMIC ENERGY AG, P250
[6]   DNB IN LIQUID-METAL HEATED FORCED CONVECTION BOILING [J].
FRANCE, DM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1973, 16 (12) :2343-2354
[7]  
FRANCE DM, 1978, ANLCT7815 ANL TECHN
[8]  
GABLER MJ, 1975, TI036610023 AI DOC
[9]  
KEBADZE BV, 1976, SOVIET ATOMIC ENERGY, V39, P870
[10]  
NEKRASOV AV, 1976, SOVIET AT ENERGY, V36, P595