PULSE OXIMETRY MONITORING OUTSIDE THE INTENSIVE-CARE UNIT - PROGRESS OF PROBLEM

被引:25
作者
BOWTON, DL [1 ]
SCUDERI, PE [1 ]
HARRIS, L [1 ]
HAPONIK, EF [1 ]
机构
[1] WAKE FOREST UNIV, BOWMAN GRAY SCH MED, DEPT ANESTHESIA, CRIT CARE SECT, WINSTON SALEM, NC 27157 USA
关键词
OXIMETRY; ANOXEMIA; RESPIRATORY THERAPY; MONITORING; PHYSIOLOGICAL; ARRHYTHMIAS;
D O I
10.7326/0003-4819-115-6-450
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the use of continuous pulse oximetry monitoring in general care units. Design: Hemoglobin oxygen saturation data collected prospectively by use of pulse oximetry with concurrent review of the medical record. Setting: General medical-surgical nursing units in a large, tertiary care university hospital. Patients: Forty patients on two nursing units monitored with continuous, bedside pulse oximetry at the request of their primary physicians. Measurements: All patients had continuous pulse oximetry monitoring. A research associate visited the bedside two or three times daily and recorded saturation compared with time data from the previous 8.75 hours. Patients were studied for 36 hours or until pulse oximetry monitoring was discontinued. Episodes of desaturation were counted. Patient charts were reviewed for documentation of desaturation in either nursing or physician notes. Orders adjusting oxygen therapy or other respiratory therapy within 12 hours of any desaturation episode were also recorded. Main Results: Thirty of the 40 patients (75%) had at least one episode of desaturation to less than 90%; 23 (58%) had at least one episode to less than 85%. Desaturation episodes were documented in nursing notes for only 33% of those patients who desaturated to less than 90% and in physician notes in only 7% of cases. Changes in respiratory therapy were ordered in 20% of patients who desaturated to less than 90% and in only 26% who desaturated to less than 85%. Conclusions: Despite their repeated occurrence, episodes of hypoxemia were rarely documented in either nursing or physician notes. Further, even in patients who had episodic desaturation, pulse oximetry monitoring had little effect on changes in physician-directed respiratory care.
引用
收藏
页码:450 / 454
页数:5
相关论文
共 12 条
  • [1] CONTINUOUS OXYGEN-SATURATION MONITORING DURING CARDIAC-CATHETERIZATION IN ADULTS
    DODSON, SR
    HENSLEY, FA
    MARTIN, DE
    LARACH, DR
    MORRIS, DL
    [J]. CHEST, 1988, 94 (01) : 28 - 31
  • [2] EICHHORN JH, 1986, JAMA-J AM MED ASSOC, V256, P1017
  • [3] CRITICAL INCIDENTS DETECTED BY PULSE OXIMETRY DURING ANESTHESIA
    MCKAY, WPS
    NOBLE, WH
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1988, 35 (03): : 265 - 269
  • [4] NONINVASIVE DETECTION OF PROFOUND ARTERIAL DESATURATIONS USING A PULSE OXIMETRY DEVICE
    MIHM, FG
    HALPERIN, BD
    [J]. ANESTHESIOLOGY, 1985, 62 (01) : 85 - 87
  • [5] ROUTINE OXIMETRY - A 5TH VITAL SIGN
    NEFF, TA
    [J]. CHEST, 1988, 94 (02) : 227 - 227
  • [6] PROUGH DS, 1990, CRITICAL CARE STATE, P271
  • [7] PULSE OXIMETRY - USES AND ABUSES
    SCHNAPP, LM
    COHEN, NH
    [J]. CHEST, 1990, 98 (05) : 1244 - 1250
  • [8] RELATIONSHIP OF VENTRICULAR ECTOPY TO OXYHEMOGLOBIN DESATURATION IN PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA
    SHEPARD, JW
    GARRISON, MW
    GRITHER, DA
    DOLAN, GF
    [J]. CHEST, 1985, 88 (03) : 335 - 340
  • [9] RELATIONSHIP OF VENTRICULAR ECTOPY TO NOCTURNAL OXYGEN DESATURATION IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE
    SHEPARD, JW
    GARRISON, MW
    GRITHER, DA
    EVANS, R
    SCHWEITZER, PK
    [J]. AMERICAN JOURNAL OF MEDICINE, 1985, 78 (01) : 28 - 34
  • [10] OXIMETER STUDIES ON PATIENTS WITH CHRONIC OBSTRUCTIVE EMPHYSEMA, AWAKE AND DURING SLEEP
    TRASK, CH
    CREE, EM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1962, 266 (13) : 639 - &