DETERMINATION OF PHENOXYACID HERBICIDES IN WATER

被引:35
作者
GEERDINK, RB
GRAUMANS, AMBC
VIVEEN, J
机构
[1] Institute for Inland Water Management and Waste Water Treatment, 8200 AA Lelystad
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 547卷 / 1-2期
关键词
D O I
10.1016/S0021-9673(01)88676-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel clean-up techniques for a polymeric precolumn (PLRP-S) for the subsequent determination of bentazone and eight phenoxy acid herbicides in surface water samples are described. After preconcentration of the components at pH 3 on a 10 x 2 mm I.D. precolumn, the technique consists of a clean-up with 1000-mu-l of 0.1 mol/l sodium hydroxide solution (pH 12.5) and of a heartcut consisting of four precolumn bed volumes of eluent directed to waste followed by ten precolumn bed volumes of eluent directed to the analytical column. Analytical separation is performed with acetonitrile water (30:70) containing 0.005 mol/l of tetrabutylammonium hydrogensulphate (pH 8.3) (which is also the desorption eluent during heartcutting) on a polymeric analytical column (PLRP-S). With 25 ml of surface water, spiked at 0.25 and 1-mu-g/l, applied to the precolumn, recoveries for all components were over 85% with a relative standard deviation (n = 5) of ca. 9% at 0.25-mu-g/l and ca. 2% at 1-mu-g/l. Detection limits in surface water samples are 0.05-0.1-mu-g/l. Owing to automation, the total analysis time is ca. 30 min.
引用
收藏
页码:478 / 483
页数:6
相关论文
共 9 条
[1]   SIMPLE PRECOLUMN SAMPLE ENRICHMENT IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR DETERMINATION OF PHENOXY ACID HERBICIDES IN WATER SAMPLES FROM EXPOSURE STUDIES [J].
AKERBLOM, M .
JOURNAL OF CHROMATOGRAPHY, 1985, 319 (03) :427-431
[2]   PROCEDURES FOR DIRECT INJECTIONS OF UNTREATED BLOOD-PLASMA INTO LIQUID-CHROMATOGRAPHIC COLUMNS WITH EMPHASIS ON A PRE-COLUMN VENTING TECHNIQUE [J].
ARVIDSSON, T ;
WAHLUND, KG ;
DAOUD, N .
JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC) :213-226
[3]   DETERMINATION OF PHENOXYACID HERBICIDES IN WATER - POLYMERIC PRE-COLUMN PRECONCENTRATION AND TETRABUTYL-AMMONIUM ION-PAIR SEPARATION ON A PRP-1 COLUMN [J].
GEERDINK, RB ;
VANBALKOM, CAA ;
BROUWER, HJ .
JOURNAL OF CHROMATOGRAPHY, 1989, 481 :275-285
[4]   DETERMINATION OF ANILINE DERIVATIVES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
GEERDINK, RB .
JOURNAL OF CHROMATOGRAPHY, 1988, 445 (01) :273-281
[5]   ANALYSIS OF BROMACIL, DIURON AND 3,4-DICHLOROANILINE IN CONTAMINATED WELL WATER, USING A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMN-SWITCHING PROCEDURE [J].
GOEWIE, CE ;
HOGENDOORN, EA .
JOURNAL OF CHROMATOGRAPHY, 1987, 410 (01) :211-216
[6]  
SCHOENMAKERS PJ, 1986, J CHROMATOGRAPHY LIB, V35
[7]   LC ENRICHMENT, SEPARATION, AND DETERMINATION OF CHLOROPHENOLS AND PHENOXYACETIC ACIDS ON PRP-1 [J].
SMITH, RL ;
PIETRZYK, DJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1983, 21 (06) :282-287
[8]   PREPARATIVE ISOLATION OF AQUATIC HUMIC SUBSTANCES [J].
THURMAN, EM ;
MALCOLM, RL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (04) :463-466
[9]   REVERSED-PHASE ION-PAIR PARTITION CHROMATOGRAPHY OF PHENYLACETIC, MANDELIC AND PYRIDINECARBOXYLIC ACID-DERIVATIVES [J].
WAHLUND, KG ;
LUND, U .
JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7) :269-276