MULTICHANNEL FLOW-INJECTION-ANALYSIS BIOSENSOR SYSTEM FOR ONLINE MONITORING OF GLUCOSE, LACTATE, GLUTAMINE, GLUTAMATE AND AMMONIA IN ANIMAL-CELL CULTURE

被引:23
作者
BLANKENSTEIN, G
SPOHN, U
PREUSCHOFF, F
THOMMES, J
KULA, MR
机构
[1] UNIV DUSSELDORF,INST ENZYME TECHNOL,D-52404 JULICH,GERMANY
[2] UNIV HALLE WITTENBERG,INST BIOTECHNOL,D-06120 HALLE,GERMANY
关键词
D O I
10.1111/j.1470-8744.1994.tb00319.x
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The application of a chemiluminometric method for the on-line monitoring of a hybridoma cell culture is described. Enzyme sensors for glucose, lactate, glutamine, glutamate and ammonia, based on oxidase-catalysed reactions, were developed and connected to a flow-injection-analysis (f.i.a.) biosensor. H2O2 produced by the oxidase-catalysed enzyme reaction was detected by luminol chemiluminescence with a fibre-optic H2O2 biosensor. The system has been used to monitor animal cell cultures. A continuous hybridoma cell cultivation for the production of monoclonal antibodies is presented as an example. It was possible to monitor the bioprocess over a period of 15 days. A complete analysis of all five components could be performed within 42 min. The enzyme sensors were stable during the whole cultivation time without significant loss of activity. The computer-controlled biosensor f.i.a. works with good reliability. The precision for all five components ranged between 2.2 and 4.5%. It was possible to determine glutamine in one step using an anti-interference enzyme reactor. Endogenous glutamate was completely removed up to a level of 0.5 mM.
引用
收藏
页码:291 / 307
页数:17
相关论文
共 23 条
[1]  
Bergmeyer Beutler, 1990, AMMONIA METHODS ENZY
[2]   CELL PERMEABILIZATION AS A TOOL FOR MEASUREMENT OF INTRACELLULAR ENZYME-ACTIVITY IN A FLOW-INJECTION SYSTEM [J].
BLANKENSTEIN, G ;
KULA, MR .
ANALYTICA CHIMICA ACTA, 1991, 248 (02) :371-378
[3]   DETERMINATION OF L-GLUTAMATE AND L-GLUTAMINE BY FLOW-INJECTION ANALYSIS AND CHEMILUMINESCENCE DETECTION - COMPARISON OF AN ENZYME COLUMN AND ENZYME MEMBRANE SENSOR [J].
BLANKENSTEIN, G ;
PREUSCHOFF, F ;
SPOHN, U ;
MOHR, KH ;
KULA, MR .
ANALYTICA CHIMICA ACTA, 1993, 271 (02) :231-237
[4]   THE EFFECT OF PH ON THE TOXICITY OF AMMONIA TO A MURINE HYBRIDOMA [J].
DOYLE, C ;
BUTLER, M .
JOURNAL OF BIOTECHNOLOGY, 1990, 15 (1-2) :91-100
[5]   REDUCTION OF WASTE PRODUCT EXCRETION VIA NUTRIENT CONTROL - POSSIBLE STRATEGIES FOR MAXIMIZING PRODUCT AND CELL YIELDS ON SERUM IN CULTURES OF MAMMALIAN-CELLS [J].
GLACKEN, MW ;
FLEISCHAKER, RJ ;
SINSKEY, AJ .
BIOTECHNOLOGY AND BIOENGINEERING, 1986, 28 (09) :1376-1389
[6]   BIOSENSING DEVICES FOR THE SEMI-AUTOMATED CONTROL OF DEHYDROGENASE SUBSTRATES IN FERMENTATIONS [J].
KITTSTEINEREBERLE, R ;
OGBOMO, I ;
SCHMIDT, HL .
BIOSENSORS, 1989, 4 (02) :75-85
[7]  
LULLAU E, 1992, ANIMAL CELL TECHNOLOGY : DEVELOPMENTS, PROCESSES AND PRODUCTS, P469
[8]  
Lund P, 1986, METHOD ENZYMAT AN, V8, P357
[9]  
MALE KB, 1993, ENZYME MICROB TECHNO, V266, P309
[10]  
MCQUEEN A, 1991, BIOPROCESS ENG, V6, P49