EVALUATION OF NEW RAPID OFFICE TEST FOR MICROALBUMINURIA AND ITS COMPARISON TO FULLY QUANTITATIVE RADIOIMMUNOASSAY

被引:6
作者
NEUMAN, RG
BONOMINI, LV
BRAUNSTEIN, SN
机构
[1] UNIV PENN,DEPT MED,PHILADELPHIA,PA 19104
[2] UNIV PARMA,DEPT ENDOCRINOL,I-43100 PARMA,ITALY
关键词
D O I
10.2337/diacare.13.10.1069
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A novel enzyme-linked immunosorbent assay (ELISA [Dialbumin]) for rapid office measurement of microalbuminuria was evaluated and its performance compared with that of a commercially available radioimmunoassay (double-antibody albumin). Urine samples containing between 0.75 and 1800 μg/ml of albumin were obtained from 31 diabetic patients and assayed by both methods. A comparison of the paired values obtained from the two methods gave a correlation coefficient of >0.99. The Dialbumin assay, which used detachable eight-well strips (1 strip/sample), 10-min incubation, tap water wash, and a 2-min color development step, was read on both an ELISA reader and a hand-held analytical device (Acc-U-Dial) designed specifically for this test. The findings of this study indicate that the Dialbumin assay, used in conjunction with the Acc-U-Dial device, affords a rapid, convenient, and sensitive method for quantitative determination of a broad range (0.3-1280 μg/ml) of urinary albumin levels in the office setting.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 10 条
[1]   GLOMERULAR-LESIONS AND URINARY ALBUMIN EXCRETION IN TYPE-I DIABETES WITHOUT OVERT PROTEINURIA [J].
CHAVERS, BM ;
BILOUS, RW ;
ELLIS, EN ;
STEFFES, MW ;
MAUER, SM .
NEW ENGLAND JOURNAL OF MEDICINE, 1989, 320 (15) :966-970
[2]  
COLWELL M, 1989, CLIN CHEM, V35, P1252
[3]   PREDICTING DIABETIC NEPHROPATHY IN INSULIN-DEPENDENT PATIENTS [J].
MOGENSEN, CE ;
CHRISTENSEN, CK .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 311 (02) :89-93
[5]   URINARY ALBUMIN EXCRETION DURING EXERCISE IN JUVENILE DIABETES - PROVOCATION TEST FOR EARLY ABNORMALITIES [J].
MOGENSEN, CE ;
VITTINGHUS, E .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1975, 35 (04) :295-300
[6]   SINGLE-VOID URINE SAMPLES CAN BE USED TO ESTIMATE QUANTITATIVE MICROALBUMINURIA [J].
NATHAN, DM ;
ROSENBAUM, C ;
PROTASOWICKI, VD .
DIABETES CARE, 1987, 10 (04) :414-418
[7]   IMPROVED COMPETITIVE ENZYME-LINKED IMMUNOASSAY (ELISA) FOR ALBUMINURIA [J].
NEUMAN, RG ;
COHEN, MP .
CLINICA CHIMICA ACTA, 1989, 179 (03) :229-237
[8]   EARLY DETECTION OF PATIENTS AT RISK OF DEVELOPING DIABETIC NEPHROPATHY - A LONGITUDINAL-STUDY OF URINARY ALBUMIN EXCRETION [J].
PARVING, HH ;
OXENBOLL, B ;
SVENDSEN, PA ;
CHRISTIANSEN, JS ;
ANDERSEN, AR .
ACTA ENDOCRINOLOGICA, 1982, 100 (04) :550-555
[9]  
VIBERTI GC, 1982, LANCET, V1, P1430
[10]   INCREASED GLOMERULAR PERMEABILITY TO ALBUMIN INDUCED BY EXERCISE IN DIABETIC SUBJECTS [J].
VIBERTI, GC ;
JARRETT, RJ ;
MCCARTNEY, M ;
KEEN, H .
DIABETOLOGIA, 1978, 14 (05) :293-300