THIN HYDROXYAPATITE COATING PRODUCED BY THE ION-BEAM DYNAMIC MIXING METHOD

被引:172
作者
YOSHINARI, M
OHTSUKA, Y
DERAND, T
机构
[1] ULVAC JAPAN LTD,INST SUPER MAT,TSUKUBA,IBARAKI 30026,JAPAN
[2] LUND UNIV,FAC DENT,DEPT ORAL TECHNOL,S-21421 MALMO,SWEDEN
关键词
HYDROXYAPATITE; COATINGS; ION BEAM DYNAMIC MIXING METHODS; SOLUBILITY; BOND STRENGTH;
D O I
10.1016/0142-9612(94)90019-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An ion beam dynamic mixing (IBDM) method was used to produce thin hydroxyapatite coatings on titanium substrates. Structure, solubility and bond strength of coatings were evaluated. The hydroxyapatite-type structure was obtained from heat-treated coatings. As-coated coatings seemed to be almost dissolved within 1 d in Hanks' solution. The thin layer of films, however, was recognized with a firm intermediate compound (such as Ti3P4) to the substrate by X-ray photoelectron spectroscopy, indicating the high tensile bond strengths from the as-coated films. Although slight reductions of the bond strength were observed in heat-treated specimens, the strengths were not reduced by immersion in Hanks' solution for 30 d.
引用
收藏
页码:529 / 535
页数:7
相关论文
共 39 条
[1]   AN ULTRASTRUCTURAL CHARACTERIZATION OF THE INTERFACE BETWEEN BONE AND SPUTTERED TITANIUM OR STAINLESS-STEEL SURFACES [J].
ALBREKTSSON, T ;
HANSSON, HA .
BIOMATERIALS, 1986, 7 (03) :201-205
[2]  
ALBREKTSSON T, 1991, BONE BIOMATERIAL INT, P1
[3]   BIOACTIVE GLASS CERAMIC ON TITANIUM SUBSTRATE - THE EFFECT OF MOLYBDENUM AS AN INTERMEDIATE BOND COATING [J].
BARTH, E ;
HERO, H .
BIOMATERIALS, 1986, 7 (04) :273-276
[4]   INHIBITION OF APATITE FORMATION BY TITANIUM AND VANADIUM IONS [J].
BLUMENTHAL, NC ;
COSMA, V .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH-APPLIED BIOMATERIALS, 1989, 23 (A1) :13-22
[5]   ION-IMPLANTATION OF SURGICAL TI-6AL-4V FOR IMPROVED RESISTANCE TO WEAR-ACCELERATED CORROSION [J].
BUCHANAN, RA ;
RIGNEY, ED ;
WILLIAMS, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1987, 21 (03) :355-366
[6]  
Cook S D, 1987, Int J Oral Maxillofac Implants, V2, P15
[7]   THE ADVANTAGES OF COATED TITANIUM IMPLANTS PREPARED BY RADIOFREQUENCY SPUTTERING FROM HYDROXYAPATITE [J].
COOLEY, DR ;
VANDELLEN, AF ;
BURGESS, JO ;
WINDELER, AS .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 67 (01) :93-100
[8]   BIOGLASS COATINGS AND BIOGLASS COMPOSITES AS IMPLANT MATERIALS [J].
DUCHEYNE, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (03) :273-291
[9]   THE EFFECT OF PLASMA-SPRAYED CALCIUM-PHOSPHATE CERAMIC COATINGS ON THE METAL-ION RELEASE FROM POROUS TITANIUM AND COBALT-CHROMIUM ALLOYS [J].
DUCHEYNE, P ;
HEALY, KE .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12) :1137-1163
[10]   STRUCTURAL-ANALYSIS OF HYDROXYAPATITE COATINGS ON TITANIUM [J].
DUCHEYNE, P ;
VANRAEMDONCK, W ;
HEUGHEBAERT, JC ;
HEUGHEBAERT, M .
BIOMATERIALS, 1986, 7 (02) :97-103