We constructed a new forward calorimeter which covers a small polar angular region in the TOPAZ detector at the TRISTAN e+e- storage ring of KEK. It comprises large BGO crystals with a silicon photodiode readout system for energy measurements, and silicon strip detectors for position measurements. It has been operating since November 1989. We present detailed design considerations and the performance from test beam measurements and e+e- colliding beam experiments. We also show the results of luminosity measurements and discuss the systematic errors.
引用
收藏
页码:202 / 216
页数:15
相关论文
共 11 条
[1]   THE CONSTRUCTION OF THE L3 EXPERIMENT [J].
ADEVA, B ;
AGUILARBENITEZ, M ;
AKBARI, H ;
ALCARAZ, J ;
ALOISIO, A ;
ALVAREZTAVIEL, J ;
ALVERSON, G ;
ALVIGGI, MG ;
ANDERHUB, H ;
ANDERSON, AL ;
ANGELOV, AM ;
ANGELOV, TH ;
ANTCHEV, GH ;
ANTONOV, L ;
ANTREASYAN, D ;
AREFIEV, A ;
ATANASOV, IH ;
AUROY, B ;
AYAD, R ;
AYRANOV, OL ;
AZEMOON, T ;
AZIZ, T ;
BACHMANN, U ;
BAHLER, P ;
BAKKEN, JA ;
BAKSAY, L ;
BALDINGER, H ;
BALL, RC ;
BALLANSAT, J ;
BANERJEE, S ;
BAO, J ;
BARBIER, G ;
BARONE, L ;
BASTI, G ;
BAY, A ;
BEAUVAIS, F ;
BECKER, U ;
BEISSEL, R ;
BENDIG, S ;
BENE, P ;
BERDUGO, J ;
BERGES, P ;
BERTHET, M ;
BERTSCH, Y ;
BETEV, BL ;
BILAND, A ;
BISCHOFF, A ;
BISCHOPS, M ;
BIZZARRI, R ;
BLAISING, JJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (1-2) :35-102
[2]   PRECISION LUMINOSITY MONITOR FOR USE AT ELECTRON-POSITRON STORAGE RINGS [J].
CRAWFORD, JF ;
HUGHES, EB ;
ONEILL, LH ;
RAND, RE .
NUCLEAR INSTRUMENTS & METHODS, 1975, 127 (02) :173-182
[3]   A CATHODE READOUT GAS SAMPLING CALORIMETER WITH CONDUCTIVE PLASTIC TUBES [J].
FUJII, K ;
FUJIMOTO, J ;
HAYASHII, H ;
KAJIKAWA, R ;
MASATANI, Y ;
OZAKI, H ;
SUGIYAMA, A ;
SUZAKI, R ;
SUZUKI, S ;
TSUKAMOTO, TY ;
TSUKAMOTO, TF ;
UNO, S ;
IWATA, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 236 (01) :55-63
[4]   A GAS SAMPLING ELECTROMAGNETIC CALORIMETER USING CONDUCTIVE PLASTIC TUBES [J].
FUJIMOTO, J ;
KAJIKAWA, R ;
KURODA, S ;
OZAKI, H ;
MASUDA, H ;
SUGIYAMA, A ;
SUZUKI, S ;
TAKAHASHI, T ;
TSUKAMOTO, TF ;
TSUKAMOTO, TY ;
UEDA, M ;
UNO, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 256 (03) :449-456
[5]   TOPAZ BARREL ELECTROMAGNETIC CALORIMETER AT TRISTAN, KEK [J].
KAWABATA, S ;
SUGAHARA, R ;
TAUCHI, T ;
UJIIE, N ;
WATANABE, Y ;
KURODA, S ;
SUWADA, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 270 (01) :11-20
[6]  
NELSON WR, SLACREP256
[7]   THE TOPAZ LUMINOSITY MONITOR AT KEK [J].
NOGUCHI, S ;
HAYASHII, H ;
FUJIWARA, N ;
YAMASHITA, S ;
IIDA, N ;
NISHIWAKI, N ;
WATANABE, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 271 (03) :404-416
[9]   HIGHLY STABLE SILICON PIN PHOTODIODE [J].
YAMAMOTO, K ;
FUJII, Y ;
KOTOOKA, Y ;
KATAYAMA, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 253 (03) :542-547
[10]  
KEKTOPAZ884