RETENTION INDEXES FOR PROGRAMMED-TEMPERATURE CAPILLARY-COLUMN GAS-CHROMATOGRAPHY OF POLYCYCLIC AROMATIC-HYDROCARBONS

被引:503
作者
LEE, ML
VASSILAROS, DL
WHITE, CM
NOVOTNY, M
机构
[1] INDIANA UNIV,DEPT CHEM,BLOOMINGTON,IN 47401
[2] US DEPT ENERGY,PITTSBURGH ENERGY TECHNOL CTR,PITTSBURGH,PA 15213
关键词
D O I
10.1021/ac50042a043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study the retention index which employs a homologous series of n-alkanes as internal standards was evaluated for use with SE-52 capillary columns, and was found to lack good statistical reliability for the PAH. Therefore, a new retention index was defined based on the series of PAH internal standards: naphthalene, phenanthrene, chrysene, and picene. The retention indices of over 200 PAH were determined using this system. The average 95% confidence limits for four measurements on each PAH are ±0.25 Index unit. © 1979, American Chemical Society. All rights reserved.