SINGLE MINI-CATHETER TECHNIQUE FOR ABDOMINAL AORTOGRAPHY AND SELECTIVE INJECTION

被引:7
作者
HAWKINS, IF [1 ]
HASEMAN, MK [1 ]
GELFAND, PN [1 ]
机构
[1] LEESBURG GEN HOSP,LEESBURG,FL
关键词
D O I
10.1148/132.3.755
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A single mini-catheter technique for abdominal aortography and selective injection using 4.1 and 5 french polyethylene catheters in the Shepherd's Crook configuration is described. Studies made in 365 patients were of high quality and without complications. This technique is easily learned, less time consuming, and safer than previous pig-tailed mini-catheter and larger catheter techniques.
引用
收藏
页码:755 / 757
页数:3
相关论文
共 7 条
[2]   APPLICATION OF A NEW TORQUE WIRE IN VISCERAL, EXTREMITY, AND NEURO-ANGIOGRAPHY [J].
HAWKINS, IF ;
MELICHAR, FA .
RADIOLOGY, 1977, 125 (03) :821-822
[3]   PRISCOLINE AND EPINEPHRINE IN SELECTIVE PANCREATIC ANGIOGRAPHY - COMPARISON STUDY USING HIGH-PRESSURE INJECTION, VALSALVA MANEUVER AND GEOMETRIC MAGNIFICATION [J].
HAWKINS, IF ;
KAUDE, JV ;
MACGREGOR, A .
RADIOLOGY, 1975, 116 (02) :311-321
[4]   PRISCOLINE IN BONE AND SOFT-TISSUE ANGIOGRAPHY [J].
HAWKINS, IF ;
HUDSON, T .
RADIOLOGY, 1974, 110 (03) :541-546
[5]   ANGIOGRAPHY OF GALLBLADDER AND BILIARY-TRACT [J].
KAUDE, JV ;
HAWKINS, IF .
SEMINARS IN ROENTGENOLOGY, 1976, 11 (03) :191-195
[6]   MAXIMUM FLOW-RATES FOR MICRO-CATHETERS [J].
MANI, RL ;
KELLETT, MJ .
RADIOLOGY, 1977, 122 (03) :831-832
[7]   USE OF A 5 FRENCH CATHETER WITH MULTIPLE SIDE HOLES IN ABDOMINAL AORTOGRAPHY [J].
MANI, RL ;
HELMS, CA ;
EISENBERG, RL .
RADIOLOGY, 1977, 123 (01) :233-234