LUMEN DEFINITION IN MR ANGIOGRAPHY

被引:18
作者
LIN, WL
HAACKE, EM
SMITH, AS
机构
[1] Department of Radiology, MRI, University Hospitals of Cleveland, Cleveland, Ohio, 44106
[2] Department of Biomedical Engineering, Case Western Reserve University, Cleveland
[3] Department of Physics, Case Western Reserve University, Cleveland
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1991年 / 1卷 / 03期
关键词
ARTIFACT; BLOOD VESSELS; MR STUDIES; 9-STAR.1214; CEREBRAL BLOOD VESSELS; 17.1214; IMAGE PROCESSING; MOTION COMPENSATION; PULSE SEQUENCES; RAPID IMAGING; 3-DIMENSIONAL IMAGING; VASCULAR STUDIES;
D O I
10.1002/jmri.1880010311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Factors affecting blood vessel lumen definition for two-dimensional and three-dimensional inflow magnetic resonance (MR) imaging methods are considered. Vessel definition is affected (a) by the amount of dephasing of the blood in the vessels, both for uncompensated and velocity-compensated gradients; (b) by the image reconstruction technique (normal Fourier reconstruction when asymmetric echoes are collected or a maximum-intensity projection technique in post-processing); (c) by loss of signal due to T2* dephasing; (d) by misregistration; (e) by vessel wall motion; and (f) by partial-volume effects. The first two factors were found to dominate for resolution on the order of 1 mm3. To overcome these dephasing problems, the authors developed asymmetric echo, velocity-compensated sequences with TEs as short as 4.8 msec. The data were then reconstructed with an iterative partial Fourier algorithm, enabling improved lumen definition to be obtained in phantoms and in vivo.
引用
收藏
页码:327 / 336
页数:10
相关论文
共 28 条
  • [1] Lenz GW, Haacke EM, Masaryk TJ, Laub GA, In‐plane vascular imaging: pulse sequence design and strategy, Radiology, 166, pp. 875-882, (1988)
  • [2] Laub GA, Kaiser WA, MR angiography with gradient motion refocusing, J Comput Assist Tomogr, 12, pp. 377-382, (1988)
  • [3] Masaryk TJ, Modic MT, Ruggieri PM, Et al., Three‐dimensional (volume) gradient‐echo imaging of the carotid bifurcation: preliminary clinical experience, Radiology, 171, pp. 801-806, (1989)
  • [4] Ruggieri PM, Laub GA, Masaryk TJ, Modic MT, Intracranial circulation: pulse‐sequence considerations in three‐dimensional (volume) MR angiography, Radiology, 171, pp. 785-791, (1989)
  • [5] Masaryk TJ, Ross JS, Modic MT, Lenz GW, Haacke EM, Carotid bifurcation: MR imaging, Radiology, 166, pp. 461-466, (1988)
  • [6] Masaryk TJ, Modic MT, Ross JS, Et al., Intracranial circulation: preliminary clinical results with three‐dimensional (volume) MR angiography, Radiology, 171, pp. 793-799, (1989)
  • [7] Dumoulin CL, Cline HE, Souza SP, Wegh MA, Walker MF, Three‐dimensional time‐of‐flight magnetic resonance angiography using spin saturation, Magn Reson Med, 11, pp. 35-46, (1989)
  • [8] Lee JN, Riederer SJ, Pelc NJ, Flow‐compensated limited flip angle MR angiography, Magn Reson Med, 12, pp. 1-13, (1989)
  • [9] Haacke EM, Masaryk TJ, Wielopolski P, Et al., Optimizing blood vessel contrast in fast three‐dimensional magnetic resonance imaging, Magn Reson Med, 14, pp. 202-221, (1990)
  • [10] Haacke EM, Lenz GW, Improving image quality in the presence of motion by using rephasing gradients, AJR, 148, pp. 1251-1258, (1987)