DETERMINATION AND IDENTIFICATION OF AMILORIDE IN HUMAN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND GAS CHROMATOGRAPHY-MASS SPECTROMETRY

被引:20
作者
BI, HG
COOPER, SF
COTE, MG
机构
[1] Institut National de la Recherche Scientifique, INRS-Santé, Université du Québec, Pointe-Claire, Que. H9R 1G6
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1992年 / 582卷 / 1-2期
关键词
D O I
10.1016/0378-4347(92)80307-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive high-performance liquid chromatographic method was developed to screen and determine amiloride (1) in human urine. The detection limit of the method is 0.12 mug/ml and the recovery of amiloride from urine was 80.4-85.5% at different concentrations. The coefficients of variation were less than 2.8 and 4.4% for intra- and inter-assays, respectively. Total urinary excretion of I in 24 h after oral administration of 5 mg or 15 mg of I ranged from 22.0 to 33.3% of the total dose for three different subjects. I could be detected in urine up to at least 44 h after a 5-mg dose and 72 h after a 15-mg dose. A gas chromatographic-mass spectrometric (GC-MS) confirmatory method was established based on the methanolysis of I to methyl 3,5-diamino-6-chloropyrazine-carboxylate (II). The di-N-trimethylsilyl derivative of II showed very good GC-MS properties and provided reliable structure information for confirmation analysis of I. This is the first time that a reliable GC-MS method has been reported for the detection of urinary I.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 17 条
[1]   SOLID-PHASE EXTRACTION TECHNIQUES FOR ASSAY OF DIURETICS IN HUMAN URINE SAMPLES [J].
CAMPINSFALCO, P ;
HERRAEZHERNANDEZ, R ;
SEVILLANOCABEZA, A .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (19) :3575-3590
[2]   COMPREHENSIVE SCREENING-PROCEDURE FOR DIURETICS IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COOPER, SF ;
MASSE, R ;
DUGAL, R .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (01) :65-88
[3]  
Cragoe EJ, 1964, Patent No. [BE639386, 639386]
[4]   SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE MEASUREMENT OF AMILORIDE IN BODY-FLUIDS [J].
FORREST, G ;
MCINNES, GT ;
FAIRHEAD, AP ;
THOMPSON, GG ;
BRODIE, MJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 428 (01) :123-130
[5]  
Li Y.W., 1991, CLIN CHEM LETT, V2, P19
[6]   STUDIES ON ANABOLIC-STEROIDS .7. ANALYSIS OF URINARY METABOLITES OF FORMEBOLONE IN MAN BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
MASSE, R ;
BI, HG ;
PING, D .
ANALYTICA CHIMICA ACTA, 1991, 247 (02) :211-221
[7]  
Mazzo D.J., 1986, ANAL PROFILES DRUG S, P1
[8]  
SCHANZER W, 1988, OFFICIAL P INT ATHLE, P89
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF BASIC AMINE DRUGS IN PLASMA AND URINE USING A SILICA-GEL COLUMN AND AN AQUEOUS MOBILE PHASE .1. AMILORIDE [J].
SHI, RJY ;
BENET, LZ ;
LIN, ET .
JOURNAL OF CHROMATOGRAPHY, 1986, 377 :399-404
[10]   SENSITIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR DETERMINATION OF AMILORIDE IN BIOLOGIC FLUIDS USING AN ION-PAIR EXTRACTION METHOD [J].
SOMOGYI, A ;
KEAL, J ;
BOCHNER, F .
THERAPEUTIC DRUG MONITORING, 1988, 10 (04) :463-468