EFFECTS OF A HADRON IRRADIATION ON SCINTILLATING FIBERS

被引:3
作者
ABBOTT, B
ADAMS, D
ARMSTRONG, T
ATAC, M
BAUMBAUGH, A
BAUMBAUGH, B
BINKLEY, M
BIRD, S
BISHOP, J
BISWAS, N
BROSS, AD
BUCHANAN, C
CASON, N
CHANEY, R
CHRISMAN, D
CHUNG, M
CLINE, D
COLLINS, G
CORCORAN, M
DAVIS, D
DAVIES, R
ELIAS, J
FENKER, H
FENYVES, E
FINLEY, D
FOSTER, GW
GOLDBERG, H
HAMMACK, H
HASAN, A
HEPPELMANN, S
JAQUES, J
JESIK, R
KAUFFMAN, J
KEHOE, R
KELLEY, C
KELLY, M
KENNEY, V
KEPHART, R
KIM, C
KOLTICK, D
KOLONKO, J
KUBIC, J
LEWIS, RA
LOSECCO, J
LOWERY, B
MARCHANT, J
MCILWAIN, R
MARGULIES, S
MENDEZ, H
MIETTENEN, H
机构
[1] UNIV CALIF LOS ANGELES,LOS ANGELES,CA 90024
[2] FERMILAB NATL ACCELERATOR LAB,BATAVIA,IL 60510
[3] UNIV ILLINOIS,CHICAGO,IL 60680
[4] MASSACHUSETTS COLL PHARM & ALLIED HLTH SCI,BOSTON,MA 02115
[5] UNIV NOTRE DAME,NOTRE DAME,IN 46556
[6] OAK RIDGE NATL LAB,OAK RIDGE,TN 37831
[7] PENN STATE UNIV,UNIV PK,PA 16802
[8] PHILADELPHIA COLL PHARM & SCI,PHILADELPHIA,PA 19104
[9] RICE UNIV,HOUSTON,TX 77251
[10] UNIV TEXAS,DALLAS,TX 75230
基金
美国国家科学基金会;
关键词
D O I
10.1109/23.256604
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Trackers based on scintillating-fiber technology are being considered by the Solenoidal Detector Collaboration at SSC and the D0 collaboration at Fermilab. An important issue is the effect of the radiation existing in the detector cores on fiber properties. Most studies of radiation damage in scintillators have irradiated small bulk samples rather than fibers, and have used X-rays, Co-60 gammas, or electron beams, often at accelerated rates. We have irradiated some 600 fibers in the Fermilab Tevatron C0 area, thereby obtaining a hadronic irradiation at realistic rates. Four-meter-long samples of ten Bicron polystyrene-based fiber types, maintained in air, dry nitrogen, argon, and vacuum atmospheres within stainless-steel tubes, were irradiated for seven weeks at various distances from the accelerator beam pipes. Maximum doses, measured by thermoluminescence detectors, were about 80 Krad. Fiber properties, particularly light yield and attenuation length, have been measured over a one-year period. A description of the work together with the results is presented. At the doses achieved, corresponding to a few years of actual fiber-tracking detector operation, little degradation is observed. In addition, recovery after several days' exposure to air has been noted. Properties of unirradiated samples kept in darkness show no changes after one year.
引用
收藏
页码:476 / 483
页数:8
相关论文
共 17 条
[1]  
BROSS AD, 1991, 1991 IEEE NUCL SCI S, V3, P1493
[2]  
BROSS AD, 1990, OCT P INT C CAL HIGH, P443
[3]  
CHUNG M, 1992, SDC92316
[4]  
CLOUGH R, 1990, CONCISE ENCY POLYM S, P937
[5]  
ELLISON JA, 1991, D0 NOT
[6]  
GROOM DE, 1989, NUCL INSTRUM METH A, V279, P1, DOI 10.1016/0168-9002(89)91057-7
[8]   DEGRADATION OF PLASTIC SCINTILLATOR EXPOSED TO TEVATRON TUNNEL BACKGROUND-RADIATION [J].
LINDSEY, CS ;
ANDERSON, EW ;
HOJVAT, C ;
TURKOT, F ;
BUJAK, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 254 (01) :212-214
[9]   RADIATION-DAMAGE STUDIES IN PLASTIC SCINTILLATORS WITH A 2.5-MEV ELECTRON-BEAM [J].
MAJEWSKI, S ;
BOWEN, M ;
ZORN, C ;
JOHNSON, K ;
HAGOPIAN, V ;
THOMASTON, J ;
WAHL, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (03) :500-507
[10]  
MARGULIES S, 1991, 1991 IEEE NUCL SCI S, P232