EFFECTS OF POLYMERIZATION CONTRACTION IN COMPOSITE RESTORATIONS

被引:83
作者
SAKAGUCHI, RL [1 ]
PETERS, MCRB [1 ]
NELSON, SR [1 ]
DOUGLAS, WH [1 ]
POORT, HW [1 ]
机构
[1] CATHOLIC UNIV NIJMEGEN,TRIKON,NIJMEGEN,NETHERLANDS
关键词
COMPOSITES; POLYMERIZATION; STRESS;
D O I
10.1016/0300-5712(92)90133-W
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Post-gel polymerization contraction of resin composite induces contraction stresses at the composite-tooth bond and in surrounding tooth structure. Strain gauges have been shown to be an effective method for measuring linear post-gel polymerization contraction of composites. A new model was developed in which the composite sample was bonded to and circumscribed by an acrylic ring. The model simulates a composite restoration surrounded by dentine. A strain gauge measured the deformation of the ring while a second strain gauge simultaneously recorded the dimensional change of the sample. Stresses placed on the acrylic ring as a result of polymerization contraction of the composite were calculated, based on the strains on the ring and the ring's material properties. Four composites (Heliomolar, Vivadent, Tonawanda, NY, USA; Herculite XR, Kerr Manufacturing Co., Romulus, MI, USA; P-50, 3M Co., St Paul, MN, USA; Silux Plus 3M Co.) were evaluated for polymerization contraction strain and stress on the surrounding acrylic ring during polymerization. At the end of the 60 s light application, Heliomolar demonstrated significantly lower post-gel contraction (0.12 per cent, P < 0.05) when compared to the other materials. When the strain reached an equilibrium at the end of 14 min Heliomolar continued to demonstrate lower post-gel contraction, however this was not statistically significant at P < 0.05. When the contraction stress on the surrounding acrylic ring was considered, P-50 rapidly developed and produced the largest stress values (1.7 MPa) at the end of the light application while Heliomolar produced the lowest stress values (0.3 MPa). These values, however, were not significantly different when evaluated statistically. The model appears to be a reasonable predictor of the results of polymerization contraction of composite resins. The ability to bond the composite to the acrylic through dentine bonding agents enhances its usefulness, and the simple geometry allows for relatively straightforward calculation of stress-strain relationships.
引用
收藏
页码:178 / 182
页数:5
相关论文
共 13 条
[1]   ADHESIVE BONDING OF VARIOUS MATERIALS TO HARD TOOTH TISSUES - FORCES DEVELOPING IN COMPOSITE-MATERIALS DURING HARDENING [J].
BOWEN, RL ;
NEMOTO, K ;
RAPSON, JE .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1983, 106 (04) :475-477
[2]   THE COMPETITION BETWEEN THE COMPOSITE-DENTIN BOND STRENGTH AND THE POLYMERIZATION CONTRACTION STRESS [J].
DAVIDSON, CL ;
DEGEE, AJ ;
FEILZER, A .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (12) :1396-1399
[3]   RELAXATION OF POLYMERIZATION CONTRACTION STRESSES BY FLOW IN DENTAL COMPOSITES [J].
DAVIDSON, CL ;
DEGEE, AJ .
JOURNAL OF DENTAL RESEARCH, 1984, 63 (02) :146-148
[4]  
DONLY K J, 1987, Pediatric Dentistry, V9, P22
[5]  
Eick J D, 1986, Quintessence Int, V17, P103
[6]   SETTING STRESS IN COMPOSITE RESIN IN RELATION TO CONFIGURATION OF THE RESTORATION [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1987, 66 (11) :1636-1639
[7]   RELAXATION OF POLYMERIZATION CONTRACTION SHEAR-STRESS BY HYGROSCOPIC EXPANSION [J].
FEILZER, AJ ;
DEGEE, AJ ;
DAVIDSON, CL .
JOURNAL OF DENTAL RESEARCH, 1990, 69 (01) :36-39
[8]  
LUTZ F, 1986, QUINTESSENCE INT, V17, P777
[9]   BIOPHYSICAL STRESS-ANALYSIS OF RESTORED TEETH - EXPERIMENTAL STRAIN-MEASUREMENT [J].
MORIN, DL ;
DOUGLAS, WH ;
CROSS, M ;
DELONG, R .
DENTAL MATERIALS, 1988, 4 (01) :41-48
[10]  
PETERS MCR, 1991, J DENT RES, V70, P295