A TOTAL ABSORPTION GE(LI) GAMMA RAY SPECTROMETER

被引:23
作者
KRANER, HW
CHASE, RL
机构
[1] Brookhaven National Laboratory, Upton, N.Y.
关键词
D O I
10.1109/TNS.1968.4324962
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A configuration of a large Ge(Li) detector has been developed which suppresses single, local interactions, particularly Compton scatterings. The peripheral n+ contact of a coaxial detector is split into two or more segments, and events are recorded from the central p contact if signals are coincidentally present on two segments of the n+ contact. A sum signal is derived from the central p contact through a high resolution preamplifier, and individual localization signals are taken from each segment of the n+ contact through simple voltage-sensitive preamplifiers. The maximum sensitivity of the system lies between 300 and 1300 keV where the Compton cross-section is dominant and many Compton scattered y-rays are not sufficiently energetic to escape. The total absorption mode achieves about 20% of the photopeak efficiency of the detector operated in the normal singles mode. An increase in the ratio of the full energy peaks to the Compton continuum of 10:1 is found for 60Co y-rays, and it is significantly greater for y-rays of less than 1 MeV. The use of internal detector summing of the linear signal eliminates the need for complicated external preamplifier gain adjustment and stability. Capacitively coupled, voltage-sensitive preamps on each n+ segment add negligible noise and reduce the sum signal-to-noise ratio only to the extent that the input shunt capacitance used reduces the sum signal level h+ about 10%. Thus, a 30 cc split n+ detector yields 3.9 keV 60Co resolution in the coincidence mode compared with 3.5 keV when both n+ segments are grounded. Copyright © 1968 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:381 / +
页数:1
相关论文
共 13 条
[1]   SELECTIVE RADIOACTIVATION AND MULTIPLE COINCIDENCE SPECTROMETRY IN DETERMINATION OF TRACE ELEMENTS IN BIOLOGICAL MATERIAL - MEASUREMENT OF MANGANESE [J].
BORG, DC ;
CAMPBELL, L ;
SEGEL, RE ;
KIENLE, P .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1961, 11 (01) :10-&
[2]  
CHASMAN C, PERSONAL COMMUNICATI
[3]   HIGH-RESOLUTION STUDIES OF GAMMA-RAY SPECTRA USING LITHIUM-DRIFT GERMANIUM GAMMA-RAY SPECTROMETERS [J].
EWAN, GT ;
TAVENDALE, AJ .
CANADIAN JOURNAL OF PHYSICS, 1964, 42 (11) :2286-&
[4]   LARGE VOLUME LITHIUM-DRIFTED GERMANIUM GAMMA-RAY DETECTORS [J].
FIEDLER, HJ ;
HUGHES, LB ;
KENNETT, TJ ;
PRESTWICH, WV ;
WALL, BJ .
NUCLEAR INSTRUMENTS & METHODS, 1966, 40 (02) :229-+
[5]   A SINGLE CRYSTAL GE(LI) COMPTON SPECTROMETER [J].
GRUHN, CR ;
KANE, JV ;
KELLY, WH ;
KUO, T ;
BERZINS, G .
NUCLEAR INSTRUMENTS & METHODS, 1967, 54 (02) :268-&
[6]  
HAWKINS RC, 1961, AECL1225
[7]  
KANE JV, 1966, B AM PHYS SOC, V11, P477
[8]  
PALMS JM, 1968, 11 P SSCS
[9]  
SAYRES AR, 1968, 11 P SSCS
[10]  
SCHICK W, 1965, THESIS MIT