REAL-TIME MICROCOMPUTER-BASED ANALYSIS OF SPONTANEOUS AND AUGMENTED LABOR

被引:4
作者
JACOBSON, JD [1 ]
GREGERSON, GN [1 ]
DALE, PS [1 ]
VALENZUELA, GJ [1 ]
机构
[1] SAN BERNARDINO CTY MED CTR,SAN BERNARDINO,CA 92404
关键词
D O I
10.1097/00006250-199011000-00005
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
In an attempt to develop a reproducible, objective measure of adequate uterine activity in labor, real-time measurements of intrauterine pressure amplitude and contraction frequency, interval, duration, and integral were made in 54 patients, 11 of whom received oxytocin augmentation. We determined the active pressure integral required per centimeter of cervical dilatation, expressed in kPa seconds, and the mean active pressure, expressed in kPa. The augmented group had a significantly higher mean active pressure integral per centimeter than those in normal labor (P < .01). There was a trend, which did not reach statistical significance, for subjects who required oxytocin augmentation of labor to develop a higher mean active pressure than those in normal labor. However, the correlation of any uterine contractility index (Montevideo units, Alexandria units, mean active pressure) with progress in labor was poor. We conclude that women with dysfunctional labor require more uterine activity for progress in labor than women with normally progressing labor, and that the computer-derived 'area under the curve' is not a better predictor of labor progress than Montevideo units.
引用
收藏
页码:755 / 758
页数:4
相关论文
共 10 条
[1]   OXYTOCIN TITRATION TO ACHIEVE PRESET ACTIVE CONTRACTION AREA VALUES DOES NOT IMPROVE THE OUTCOME OF INDUCED LABOR [J].
ARULKUMARAN, S ;
INGEMARSSON, I ;
RATNAM, SS .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (03) :242-248
[2]  
CREASY RK, 1984, MATERNAL FETAL MED, P473
[3]  
DALE PS, 1989, J DEV PHYSL OXF, V11, P15
[4]  
FAIRLIE FM, 1985, BR J OBSTET GYNAECOL, V92, P57
[5]   QUANTITATION OF UTERINE ACTIVITY IN 100 PRIMIPAROUS PATIENTS [J].
MILLER, FC ;
YEH, SY ;
SCHIFRIN, BS ;
PAUL, RH ;
HON, EH .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1976, 124 (04) :398-405
[6]  
ODRISCOLL K, 1984, OBSTET GYNECOL, V63, P485
[7]   UNITS FOR THE EVALUATION OF UTERINE CONTRACTILITY [J].
PHILLIPS, GF ;
CALDER, AA .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1987, 94 (03) :236-241
[8]  
SEITCHIK J, 1981, OBSTET GYNECOL, V57, P453
[9]   THE EFFECT OF OXYTOCIN INFUSION ON UTERINE ACTIVITY LEVELS IN SLOW LABOR [J].
STEER, PJ ;
CARTER, MC ;
BEARD, RW .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (11) :1120-1126
[10]   NORMAL LEVELS OF ACTIVE CONTRACTION AREA IN SPONTANEOUS LABOR [J].
STEER, PJ ;
CARTER, MC ;
BEARD, RW .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1984, 91 (03) :211-219