DOSIMETRIC VERIFICATION OF A 3-D ELECTRON PENCIL BEAM DOSE CALCULATION ALGORITHM

被引:21
作者
MCSHAN, DL [1 ]
FRAASS, BA [1 ]
TENHAKEN, RK [1 ]
机构
[1] UNIV MICHIGAN,MED CTR,DEPT RADIAT ONCOL,ANN ARBOR,MI 48109
关键词
3-D TREATMENT PLANNING; ELECTRON BEAMS; PENCIL BEAMS; DOSIMETRIC VERIFICATION;
D O I
10.1118/1.597363
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A three-dimensional electron beam dose calculational algorithm implemented for use in a three-dimensional treatment planning system is described. The 3-D electron beam calculations have been in use clinically for more than seven years. The algorithm uses a pencil beam model based on small angle multiple Coulomb scattering theory. Our implementation allows volumetric CT-based inhomogeneity corrections and provides for irregular field shapes (fields shaped with cerrobend cutouts) and the use of bolus. As part of NCI-funded work evaluating the state of the art in electron beam treatment planning, extensive algorithm verification was undertaken and results of these tests for our implementation are presented.
引用
收藏
页码:13 / 23
页数:11
相关论文
共 43 条
[1]  
ALMOND PR, 1981, P S ELECTRON BEAM TH, P43
[2]  
BIELAJEW AF, 1987, USE COMPUTERS RAD TH, P65
[3]   ELECTRON AND PHOTON BEAMS FROM A 50 MEV RACETRACK MICROTRON [J].
BRAHME, A ;
KRAEPELIEN, T ;
SVENSSON, H .
ACTA RADIOLOGICA ONCOLOGY, 1980, 19 (04) :305-319
[4]   ELECTRON-BEAM DOSE PLANNING USING DISCRETE GAUSSIAN BEAMS - MATHEMATICAL BACKGROUND [J].
BRAHME, A ;
LAX, I ;
ANDREO, P .
ACTA RADIOLOGICA ONCOLOGY, 1981, 20 (02) :147-158
[5]  
BRUINVIS IAD, 1984, 8TH P INT C US COMP, P152
[6]   ELECTRON DOSE DISTRIBUTIONS IN EXPERIMENTAL PHANTOMS - A COMPARISON WITH 2D PENCIL BEAM CALCULATIONS [J].
CYGLER, J ;
BATTISTA, JJ ;
SCRIMGER, JW ;
MAH, E ;
ANTOLAK, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1073-1086
[7]  
Fraass B. A., 1987, USE COMPUTERS RAD TH, P521
[8]  
Fraass B. A., 1987, USE COMPUTERS RAD TH, P273
[9]   INTEGRATION OF MAGNETIC-RESONANCE-IMAGING INTO RADIATION-THERAPY TREATMENT PLANNING .1. TECHNICAL CONSIDERATIONS [J].
FRAASS, BA ;
MCSHAN, DL ;
DIAZ, RF ;
TENHAKEN, RK ;
AISEN, A ;
GEBARSKI, S ;
GLAZER, G ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (12) :1897-1908
[10]  
FRAASS BA, 1990, COMPUTERIZED BEAM SH, P333