THE EFFECT OF REFRACTION AND ASSUMED SPEEDS OF SOUND IN TISSUE AND BLOOD ON DOPPLER ULTRASOUND BLOOD VELOCITY-MEASUREMENTS

被引:24
作者
CHRISTOPHER, DA [1 ]
BURNS, PN [1 ]
HUNT, JW [1 ]
FOSTER, FS [1 ]
机构
[1] ONTARIO CANC INST,TORONTO,ON M4X 1K9,CANADA
关键词
DOPPLER ULTRASOUND; BLOOD VELOCITY MEASUREMENT; REFRACTION; SPEED OF SOUND; DOPPLER ANGLE; ULTRASONICS;
D O I
10.1016/S0301-5629(94)00101-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The combined effect of three assumption's relating to refraction, the speed of sound in tissue and the speed of sound in blood on the accuracy of Doppler ultrasound blood velocity measurements has been investigated. A theoretical relationship giving the net velocity measurement error introduced by these three assumptions has been derived using a model in which tissue and blood layers are separated by straight, parallel boundaries. This net error is dependent on the assumed and actual speed of sound in tissue, the assumed speed of sound in blood and the Doppler angle, but is effectively independent of the actual speed of sound in blood, For clinical blood velocity measurements, the net error is estimated to be as much as an 8% overestimation of the actual velocity, higher than previously predicted for any of the factors individually. The relationship also predicts a net velocity measurement error in experimental flow systems and string phantoms which is dependent on the speed of sound in the liquid bath. A water bath at room temperature will give an overestimation of approximately 2%. Experimental investigations using conventional and modified string phantoms and a 5-MHz linear phased array system support these conclusions. The effect of perturbing the layers from their parallel orientation has also been considered theoretically and has provided additional support for the above conclusions. These results may help assure more accurate Doppler velocity measurements in both experimental and clinical settings.
引用
收藏
页码:187 / 201
页数:15
相关论文
共 35 条
[1]  
Atkinson P., 1982, DOPPLER ULTRASOUND I
[2]   INFLUENCE OF SPECTRAL BROADENING ON CONTINUOUS WAVE DOPPLER ULTRASOUND SPECTRA - A GEOMETRIC APPROACH [J].
BASCOM, PAJ ;
COBBOLD, RSC ;
ROELOFS, BHM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (05) :387-395
[3]   QUANTITATIVE CONTRAST MEASUREMENTS IN B-MODE IMAGES COMPARISON BETWEEN EXPERIMENT AND THEORY [J].
BLY, SHP ;
LEECHAHAL, D ;
FOSTER, DR ;
PATTERSON, MS ;
FOSTER, FS ;
HUNT, JW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1986, 12 (03) :197-208
[4]  
BURNS PN, 1985, RADIOL CLIN N AM, V23, P641
[5]  
CHRISTOPHER DA, 1992, THESIS U TORONTO
[6]   INFLUENCE OF BEAM PROFILE AND DEGREE OF INSONATION ON THE CW DOPPLER ULTRASOUND SPECTRUM AND MEAN VELOCITY [J].
COBBOLD, RSC ;
VELTINK, PH ;
JOHNSTON, KW .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (06) :364-370
[7]  
Daigle RJ, 1990, J VASC TECHNOL, V14, P206
[8]   PULSED DOPPLER ACCURACY ASSESSMENT DUE TO FREQUENCY-DEPENDENT ATTENUATION AND RAYLEIGH-SCATTERING ERROR SOURCES [J].
EMBREE, PM ;
OBRIEN, WD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (03) :322-326
[9]  
Evans D. H., 1989, DOPPLER ULTRASOUND P