A FAST INTEGRATED READOUT SYSTEM FOR A CATHODE PAD PHOTON DETECTOR

被引:16
作者
FRENCH, M
LOVELL, M
CHESI, E
RACZ, A
SEGUINOT, J
YPSILANTIS, T
ARNOLD, R
GUYONNET, JL
EGGER, J
GABATHULER, K
机构
[1] CERN,CH-1211 GENEVA 23,SWITZERLAND
[2] COLL FRANCE,F-75231 PARIS 05,FRANCE
[3] LOUIS PASTEUR UNIV,CRN,STRASBOURG,FRANCE
[4] PAUL SCHERRER INST,VILLIGEN,SWITZERLAND
关键词
D O I
10.1016/0168-9002(93)91056-S
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fast integrated electronic chain is presented to read out the cathode pad array of a multiwire photon detector for a fast RICH counter. Two VLSI circuits have been designed and produced. An analog eight-channel, low-noise, fast, bi-polar current preamplifier-amplifier and discriminator chip serves as the front-end detection electronics. It has an rms equivalent noise current of 10 nA, 50 MHz bandwidth with 10 mW of power consumption per channel. Two analog chips are coupled to a digital sixteen-channel CMOS readout chip, operating at 20 MHz with a power consumption of 6 mW per channel. Readout of a 4000 pad sector requires 2-3 mus, depending on the number of hit pads. The full RICH counter is made up of many such sectors, read out in parallel. The minimum time needed to separate successive hits on the same pad is 70 ns. The conception of the digital chip and its properties are fully presented in this report. The analog chip is described in less detail since it will be fully covered in a forthcoming paper.
引用
收藏
页码:511 / 534
页数:24
相关论文
共 5 条
[1]   A FAST-CATHODE PAD-PHOTON DETECTOR FOR CHERENKOV RING IMAGING [J].
ARNOLD, R ;
GIOMATARIS, Y ;
GUYONNET, JL ;
RACZ, A ;
SEGUINOT, J ;
YPSILANTIS, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (03) :465-494
[2]  
FRENCH M, IUNPUB FAST BIPOLAR
[3]   REFLECTIVE UV PHOTOCATHODES WITH GAS-PHASE ELECTRON EXTRACTION - SOLID, LIQUID, AND ADSORBED THIN-FILMS [J].
SEGUINOT, J ;
CHARPAK, G ;
GIOMATARIS, Y ;
PESKOV, V ;
TISCHHAUSER, J ;
YPSILANTIS, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2) :133-147
[4]   LIQUID XENON IONIZATION AND SCINTILLATION STUDIES FOR A TOTALLY ACTIVE-VECTOR ELECTROMAGNETIC CALORIMETER [J].
SEGUINOT, J ;
PASSARDI, G ;
TISCHHAUSER, J ;
YPSILANTIS, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 323 (03) :583-600
[5]  
SEGUINOT J, IN PRESS NUCL INST A