OPTIMIZING SEPARATION PARAMETERS IN CAPILLARY ISOELECTRIC-FOCUSING

被引:110
作者
ZHU, MD [1 ]
RODRIGUEZ, R [1 ]
WEHR, T [1 ]
机构
[1] BIO-RAD LABS,3300 REGATTA BLVD,RICHMOND,CA 94804
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 559卷 / 1-2期
关键词
D O I
10.1016/0021-9673(91)80095-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several modifications have been developed for capillary isoelectric focusing (IEF) to improve separation and detection of proteins. A basic compound was incorporated into the ampholyte mixture to block the segment between the monitor point and capillary end during focusing, enabling detection of basic proteins during mobilization. Use of a low-pI zwitterionic mobilization agent increased mobilization efficiency of the acidic region of the pH gradient, improving detection of acidic proteins. Mobilization with a neutral-pI zwitterion selectively mobilized neutral and basic proteins with improved resolution. Observation of colored proteins in glass capillaries mounted on thermosensitive liquid crystal was used to determine the heat generation patterns along the capillary and the effect of salt on the IEF process. The presence of salt in the sample resulted in long focusing and mobilization times. Incorporation of a non-ionic detergent in the sample plus ampholyte mixture reduced precipitation and improved reproducibility in capillary IEF of gamma-globulins.
引用
收藏
页码:479 / 488
页数:10
相关论文
共 10 条
[1]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[2]   CARRIER-FREE ZONE ELECTROPHORESIS, DISPLACEMENT ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN A HIGH-PERFORMANCE ELECTROPHORESIS APPARATUS [J].
HJERTEN, S ;
ELENBRING, K ;
KILAR, F ;
LIAO, JL ;
CHEN, AJC ;
SIEBERT, CJ ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1987, 403 :47-61
[3]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[4]   THEORETICAL AND EXPERIMENTAL-STUDY OF HIGH-PERFORMANCE ELECTROPHORETIC MOBILIZATION OF ISOELECTRICALLY FOCUSED PROTEIN ZONES [J].
HJERTEN, S ;
LIAO, JL ;
YAO, K .
JOURNAL OF CHROMATOGRAPHY, 1987, 387 :127-138
[5]   ETHYLENE GLYCOL AS A STABILIZING AGENT IN ELECTROFOCUSING [J].
JONES, RE ;
HEMMINGS, WA ;
FAULK, WP .
IMMUNOCHEMISTRY, 1971, 8 (03) :299-&
[6]   FAST AND HIGH-RESOLUTION ANALYSIS OF HUMAN-SERUM TRANSFERRIN BY HIGH-PERFORMANCE ISOELECTRIC-FOCUSING IN CAPILLARIES [J].
KILAR, F ;
HJERTEN, S .
ELECTROPHORESIS, 1989, 10 (01) :23-29
[7]   SEPARATION OF THE HUMAN TRANSFERRIN ISOFORMS BY CARRIER-FREE HIGH-PERFORMANCE ZONE ELECTROPHORESIS AND ISOELECTRIC-FOCUSING [J].
KILAR, F ;
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1989, 480 :351-357
[8]  
Righetti P. G., 1983, ISOELECTRIC FOCUSING
[9]  
WEHR T, 1990, AM BIOTECHNOL LAB, V8, P22
[10]   EXTENSION OF THE ALKALINE END OF A PH GRADIENT IN THIN-LAYER POLYACRYLAMIDE ELECTROFOCUSING GELS BY ADDITION OF N,N,N',N'-TETRAMETHYLETHYLENEDIAMINE [J].
YAOJUN, G ;
BISHOP, R .
JOURNAL OF CHROMATOGRAPHY, 1982, 234 (02) :459-462