CETYLTRIMETHYLAMMONIUM CHLORIDE AS A SURFACTANT BUFFER ADDITIVE FOR REVERSED-POLARITY CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY

被引:64
作者
VARGHESE, J [1 ]
COLE, RB [1 ]
机构
[1] UNIV NEW ORLEANS,DEPT CHEM,NEW ORLEANS,LA 70148
关键词
D O I
10.1016/0021-9673(93)83255-Q
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The rapid analysis of picomole quantities of various cationic molecules (laser dyes, tripeptides and larger bioactive peptides) has been achieved by on-line capillary electrophoresis-electrospray mass spectrometry (CE-ES-MS). Use of the cationic surfactant, cetyltrimethylammonium chloride (CTAC) in the CE buffer greatly facilitated the analyses. Under reversed-polarity conditions (negative potential at the source vial), CTAC induces electroosmotic flow towards the mass spectrometer, presumably due to the creation of a cationic layer on the inner surface of the fused-silica capillaries. CTAC diminishes analyte-capillary wall interactions, allowing efficient separations and symmetrical peak shapes. It may be used over a wide range of pH values without loss of electroosmotic flow. Added selectivity, provided by the surfactant properties of CTAC, played a critical role in resolving closely related tripeptides as well as larger (five to thirteen amino acid units) peptides. Above the critical micelle concentration of CTAC, interactions with the pseudostationary micellar phase increased selectivity even for ionic analytes.
引用
收藏
页码:369 / 376
页数:8
相关论文
共 12 条
[1]  
ALTRIA KD, 1986, ANAL P, V23, P453
[2]  
ARGHESE J, 1993, J CHROMATOGR, V639, P303
[3]   QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR WEIGHT CARBOXYLIC-ACIDS BY CAPILLARY ZONE ELECTROPHORESIS CONDUCTIVITY DETECTION [J].
HUANG, XH ;
LUCKEY, JA ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1989, 61 (07) :766-770
[4]   SEPARATION AND DETECTION OF DNA BY CAPILLARY ELECTROPHORESIS [J].
KASPER, TJ ;
MELERA, M ;
GOZEL, P ;
BROWNLEE, RG .
JOURNAL OF CHROMATOGRAPHY, 1988, 458 :303-312
[5]   CAPILLARY ELECTROPHORETIC SEPARATIONS OF PEPTIDES USING MICELLE-FORMING COMPOUNDS AND CYCLODEXTRINS AS ADDITIVES [J].
LIU, JP ;
COBB, KA ;
NOVOTNY, M .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :189-197
[6]   OPTIMIZATION OF CAPILLARY ZONE ELECTROPHORESIS ELECTROSPRAY IONIZATION PARAMETERS FOR THE MASS-SPECTROMETRY AND TANDEM MASS-SPECTROMETRY ANALYSIS OF PEPTIDES [J].
MOSELEY, MA ;
JORGENSON, JW ;
SHABANOWITZ, J ;
HUNT, DF ;
TOMER, KB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :289-300
[7]  
MOSELEY MA, 1982, J HIGH RES CHROMATOG, V5, P488
[8]  
MUKERJEE P, 1971, NATL STAND REF DATA, V36
[9]   IMPROVED ELECTROSPRAY IONIZATION INTERFACE FOR CAPILLARY ZONE ELECTROPHORESIS - MASS-SPECTROMETRY [J].
SMITH, RD ;
BARINAGA, CJ ;
UDSETH, HR .
ANALYTICAL CHEMISTRY, 1988, 60 (18) :1948-1952
[10]  
TERABE K, 26TH P INT LIQ CHROM