OPTIMIZATION OF T-2-SELECTIVE BINOMIAL PULSES FOR MAGNETIZATION-TRANSFER

被引:16
作者
PACHOTCLOUARD, M
DARRASSE, L
机构
[1] Institut d'Electronique Fondamentale, (CNRS, Université de Paris-Sud, Orsay
关键词
BINOMIAL PULSES; T-2-SELECTIVE SATURATION; MAGNETIZATION TRANSFER;
D O I
10.1002/mrm.1910340325
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate rules have been established to build binomial pulses up to fifth order, for selectively saturating protons at any given T-2 with minimum power deposition. Pulse performance and sensitivity to experimental defects have been evaluated; the third order is generally found to be best suited. It is shown, by combining theory and experiment performed at 0.1 T, that matching the saturation pulse to T-2 of the motionally restricted pool is essential to reveal exchange with free water protons, It is emphasized that, to date, lack of magnetization transfer contrast with binomial pulses is due mainly to insufficient RF level available with most MR imaging systems, especially at high magnetic field.
引用
收藏
页码:462 / 469
页数:8
相关论文
共 35 条
[1]   DETECTION OF LIVER FIBROSIS WITH MAGNETIC CROSS-RELAXATION [J].
AISEN, AM ;
DOI, K ;
SWANSON, SD .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :551-556
[2]  
BALABAN R S, 1992, Magnetic Resonance Quarterly, V8, P116
[3]   DETERMINATION OF PROTON MAGNETIZATION-TRANSFER RATE CONSTANTS IN HETEROGENEOUS BIOLOGICAL-SYSTEMS [J].
BROOKS, D ;
KUWATA, K ;
SCHLEICH, T .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) :331-336
[4]   1/T1-RHO AND LOW-FIELD 1/T1 OF TISSUE WATER PROTONS ARISE FROM MAGNETIZATION TRANSFER TO MACROMOLECULAR SOLID-STATE BROADENED LINES [J].
BROWN, RD ;
KOENIG, SH .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :145-152
[5]   MAGNETIC-RELAXATION COUPLING IN HETEROGENEOUS SYSTEMS [J].
BRYANT, RG ;
LESTER, CC .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1993, 101 (02) :121-125
[6]   NUCLEAR MAGNETIC CROSS-RELAXATION SPECTROSCOPY [J].
GRAD, J ;
BRYANT, RG .
JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (01) :1-8
[7]   QUANTITATIVE INTERPRETATION OF MAGNETIZATION-TRANSFER [J].
HENKELMAN, RM ;
HUANG, XM ;
XIANG, QS ;
STANISZ, GJ ;
SWANSON, SD ;
BRONSKILL, MJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :759-766
[8]   CORRELATION OF SPECTROSCOPY AND MAGNETIZATION-TRANSFER IMAGING IN THE EVALUATION OF DEMYELINATING LESIONS AND NORMAL APPEARING WHITE-MATTER IN MULTIPLE-SCLEROSIS [J].
HIEHLE, JF ;
LENKINSKI, RE ;
GROSSMAN, RI ;
DOUSSET, V ;
RAMER, KN ;
SCHNALL, MD ;
COHEN, JA ;
GONZALEZSCARANO, F .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :285-293
[9]   MAGNETIZATION-TRANSFER CONTRAST IMAGING OF HEPATIC NEOPLASMS [J].
HOLLETT, MD ;
AISEN, AM ;
YEUNG, HN ;
FRANCIS, IR ;
BREE, RL .
MAGNETIC RESONANCE IMAGING, 1994, 12 (01) :1-8
[10]   ESTIMATION OF BLOCH MODEL MT SPIN SYSTEM PARAMETERS FROM Z-SPECTRAL DATA [J].
HOLT, RW ;
DUERK, TL ;
HUA, J ;
HURST, GC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (02) :122-130