A REEXAMINATION OF THE PEAK CURRENT CALIBRATION OF THE NATIONAL LIGHTNING DETECTION NETWORK

被引:38
作者
IDONE, VP [1 ]
SALJOUGHY, AB [1 ]
HENDERSON, RW [1 ]
MOORE, PK [1 ]
PYLE, RB [1 ]
机构
[1] SUNY ALBANY, DEPT ATMOSPHER SCI, 1400 WASHINGTON AVE, ALBANY, NY 12222 USA
关键词
D O I
10.1029/93JD01925
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The peak current calibration of the National Lightning Detection Network (NLDN) recently reported by Orville (1991) has been reexamined with a roughly threefold larger data set of 57 directly measured stroke peak currents, I(Peak) (kiloamperes), and their corresponding NLDN mean normalized magnetic signal strengths, M(peak)BAR (LLP units). These 57 lightning strokes originated in 36 triggered lightning flashes initiated at the Kennedy Space Center (KSC), Florida, during the research campaigns of 1985-1991. Identification of corresponding I(peak) and M(peak)BAR measurements was verified through accurate coincidence in absolute time of the two independent data sets. The I(peak)-M(peak)BAR data (with one point excluded as an outlier) is apparently linearly related with a correlation coefficient of 0.88 1, consistent with that predicted by application of the transmission line model of the lightning return stroke. The regression equation for prediction of I(peak) from NLDN M(peak)BAR measurements is I(peak)=20+0.171M(peak)BAR where the slope is expressed in kiloampere/(LLP units). Examination of the overall I(peak)-M(peak)BAR data set for the possible influence of two different models of signal strength attenuation with distance, D, (power law, D(beta), and exponential, [exp(alphaD)D]-1) indicates negligible sensitivity to the proposed variations; other larger error sources Likely mask the true attenuation effect. Twelve flashes were detected with four or more direction finders; a power law fit to the direction finder signal strength variation with distance of these individual flashes yields a mean beta value of -1.09. Examination of the overall I(peak)-M(peak)BAR data set for the possible effect of a nonlinear relation between the source stroke peak current and return stroke propagation speed indicates no obvious influence. The 95% confidence bounds for peak current prediction in the mean suggest a percent uncertainty of 10-15% for peak currents between 15 and 60 kA. Similar accuracy is expected for peak currents greater than 60 kA provided care is taken to minimize possible nonlinear amplification effects in the NLDN data. Below 15 kA, the percent uncertainty rapidly increases suggesting that the inferred distribution of peak current values less than this limit may be quite unreliable.
引用
收藏
页码:18323 / 18332
页数:10
相关论文
共 34 条
[1]  
Berger K., 1975, Electra, P23
[2]  
COOK W, 1992, 1992 P INT AER GROUN, P1
[3]  
CUMMINS KL, 1992, 9 INT C ATM EL ST PE, P914
[4]   RESEARCH ON ARTIFICIALLY TRIGGERED LIGHTNING IN FRANCE [J].
FIEUX, RP ;
GARY, CH ;
HUTZLER, BP ;
EYBERTBERARD, AR ;
HUBERT, PL ;
MEESTERS, AC ;
PERROUD, PH ;
HAMELIN, JH ;
PERSON, JM .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (03) :725-733
[5]  
FISHER RJ, 1991, SAND902926 SAND NAT
[6]  
HENDERSON RW, 1989, EOS T AGU, V70, P1005
[7]  
HENDERSON RW, 1988, EOS T AGU, V69, P1070
[8]  
HERODOTOU N, 1992, 1992 IEEE PES SUMM M
[9]  
HERODOTOU N, 1990, THESIS U TORONTO TOR
[10]   TRIGGERED LIGHTNING IN NEW-MEXICO [J].
HUBERT, P ;
LAROCHE, P ;
EYBERTBERARD, A ;
BARRET, L .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1984, 89 (ND2) :2511-2521