摘要
The incorporation of platinum disk microelectrodes of various radii (2.5-50 μm) in a wall-jet flow cell offers reduced limits of detection for the determination of copper in urine by flow injection analysis compared with standard methods based on a conventional sized glassy carbon disk macroelectrode (radius 1.5 mm), in a thin-layer cell. The radius of the platinum disk microelectrode was found to be critical with respect to both the limit of detection and flow rate dependence. An optimal radius value of 28 μm was found with detection limits increasing with both larger and smaller electrode radii. In contrast, as theoretically expected, a diminished flow rate dependence was observed the smaller the radii of the platinum disk microelectrodes. Sample cleanup and preparation is conveniently achieved by the use of Sep-Pak cartridges and formation of a copper dlthiocarbamate complex. The metal complex is easily oxidized at platinum disk microelectrodes in acetonitrile, which was the solvent used in the flow Injection method of analysis. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 25 条
[1]   UNIFORMLY ACCESSIBLE ELECTRODES [J].
ALBERY, WJ ;
BRUCKENSTEIN, S .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 144 (1-2) :105-112
[2]   AMPEROMETRIC DETECTION OF PICOMOLE SAMPLES IN A MICRODISK ELECTROCHEMICAL FLOW-JET CELL WITH DILUTE SUPPORTING ELECTROLYTE [J].
BIXLER, JW ;
BOND, AM .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2859-2863
[3]   INSTRUMENTAL CONFIGURATIONS FOR THE DETERMINATION OF SUBMICROMOLAR CONCENTRATIONS OF ELECTROACTIVE SPECIES WITH CARBON, GOLD AND PLATINUM MICRODISK ELECTRODES IN STATIC AND FLOW-THROUGH CELLS [J].
BIXLER, JW ;
BOND, AM ;
LAY, PA ;
THORMANN, W ;
VANDENBOSCH, P ;
FLEISCHMANN, M ;
PONS, BS .
ANALYTICA CHIMICA ACTA, 1986, 187 :67-77
[4]   DETERMINATION OF METALS IN URINE BY DIRECT INJECTION OF SAMPLE, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROCHEMICAL OR SPECTROPHOTOMETRIC DETECTION [J].
BOND, AM ;
KNIGHT, RW ;
REUST, JB ;
TUCKER, DJ ;
WALLACE, GG .
ANALYTICA CHIMICA ACTA, 1986, 182 :47-59
[5]   STEADY-STATE VOLTAMMETRY [J].
BOND, AM ;
OLDHAM, KB ;
ZOSKI, CG .
ANALYTICA CHIMICA ACTA, 1989, 216 (1-2) :177-230
[6]   SIMULTANEOUS DETERMINATION OF COPPER, NICKEL, COBALT, CHROMIUM(VI), AND CHROMIUM(III) BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BOND, AM ;
WALLACE, GG .
ANALYTICAL CHEMISTRY, 1982, 54 (11) :1706-1712
[7]   A COMPARISON OF THE CHRONOAMPEROMETRIC RESPONSE AT INLAID AND RECESSED DISK MICROELECTRODES [J].
BOND, AM ;
LUSCOMBE, D ;
OLDHAM, KB ;
ZOSKI, CG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 249 (1-2) :1-14
[8]   FLOW-RATE INDEPENDENT AMPEROMETRIC CELL [J].
CAUDILL, WL ;
HOWELL, JO ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1982, 54 (14) :2532-2535
[9]   MASS-TRANSFER TO AN IMPINGING JET ELECTRODE [J].
CHIN, DT ;
TSANG, CH .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1978, 125 (09) :1461-1470
[10]   HYDRODYNAMIC PROPERTIES AND MASS-TRANSFER CHARACTERISTICS OF ELECTROCHEMICAL FLOW-THROUGH CELLS OF THE CONFINED WALL JET TYPE [J].
DALHUIJSEN, AJ ;
VANDERMEER, TH ;
HOOGENDOORN, CJ ;
HOOGVLIET, JC ;
VANBENNEKOM, WP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 182 (02) :295-313