THE EFFECTIVENESS OF SMOKELESS STOVES IN REDUCING INDOOR AIR-POLLUTION IN A RURAL HILL REGION OF NEPAL

被引:17
作者
PANDEY, MR [1 ]
NEUPANE, RP [1 ]
GAUTAM, A [1 ]
SHRESTHA, IB [1 ]
机构
[1] TRIBHUVAN UNIV,INST MED,KATMANDU,NEPAL
关键词
D O I
10.2307/3673493
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Personal exposure levels to respirable suspended particulates during cooking periods were monitored in twenty households in a rural community of the hill region of Nepal. Filters for gravimetric analysis were exposed in households with traditional stoves (without flue) and then again after the introduction of smokeless (with flue) cook stoves. Drager Tube analyses of carbon monoxide and formaldehyde levels were also conducted. Data from this longitudinal study provide convincing evidence of the cause-effect relationship between the introduction and use of smokeless stoves and the resulting decrease in domestic smoke pollution. A household survey revealed that all cooks, but one, found that the smokeless stove emitted less smoke than the traditional stove and seventy-five percent of the cooks preferred the smokeless stove to the traditional stove.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 10 条
[1]   INDOOR AND OUTDOOR AIR-POLLUTION IN THE HIMALAYAS [J].
DAVIDSON, CI ;
LIN, SF ;
OSBORN, JF ;
PANDEY, MR ;
RASMUSSEN, RA ;
KHALIL, MAK .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (06) :561-567
[2]  
Pandey M R, 1985, Tokai J Exp Clin Med, V10, P471
[3]   DOMESTIC SMOKE POLLUTION AND CHRONIC-BRONCHITIS IN A RURAL-COMMUNITY OF THE HILL REGION OF NEPAL [J].
PANDEY, MR .
THORAX, 1984, 39 (05) :337-339
[4]   DOMESTIC SMOKE POLLUTION AND ACUTE RESPIRATORY-INFECTIONS IN A RURAL-COMMUNITY OF THE HILL REGION OF NEPAL [J].
PANDEY, MR ;
NEUPANE, RP ;
GAUTAM, A ;
SHRESTHA, IB .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :337-340
[5]  
PANDEY MR, 1989, LANCET 0225, P427
[6]  
PANDEY MR, 1988, MONOGRAPH MRIGENDRA
[7]   COOKING IN INDIA - THE IMPACT OF IMPROVED STOVES ON INDOOR AIR-QUALITY [J].
RAMAKRISHNA, J ;
DURGAPRASAD, MB ;
SMITH, KR .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :341-352
[8]   INDOOR SMOKE EXPOSURES FROM TRADITIONAL AND IMPROVED COOKSTOVES COMPARISONS AMONG RURAL NEPALI WOMEN [J].
REID, HF ;
SMITH, KR ;
SHERCHAND, B .
MOUNTAIN RESEARCH AND DEVELOPMENT, 1986, 6 (04) :293-303
[9]  
Smith KR., 1987, BIOFUELS AIR POLLUTI
[10]  
1984, WHO80 OFFS PUBL