NONDESTRUCTIVE WOOD DENSITY DISTRIBUTION MEASUREMENTS USING COMPUTED-TOMOGRAPHY

被引:42
作者
LINDGREN, O [1 ]
DAVIS, J [1 ]
WELLS, P [1 ]
SHADBOLT, P [1 ]
机构
[1] MONASH UNIV,DEPT APPL PHYS,CAULFIELD,VIC 3145,AUSTRALIA
关键词
D O I
10.1007/BF02615356
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
Two computed tomography scanners have been used to acquire density profiles from five wooden test pieces. These test pieces had annual growth ring widths varying between about 0.6 mm and 3.5 mm. The two scanners employed were a medical scanner, a GE 9800 Quick scan system, and a purpose built microscanner constructed around a Rigaku D-Max II diffractometer. The results demonstrated that the annual growth rings could be resolved and density measurements could be reliably determined using the microscanner when the annual growth rings were about 0.9 mm or greater in width. The medical scanner could not satisfactorily measure density in earlywood or latewood regions even in samples where the annual growth ring width was of the order of 3.5 mm. A small difference in density measurements could be observed between the two scanners for the same specimens. The difference is attributed to calibration differences, the reconstruction algorithms used and the different geometries of the two systems; particularly in relation to the detector apertures. The larger detector size in the medical system results in too high or too low density values in the earlywood or the latewood respectively due to spatial averaging. However, the medical scanner provides satisfactory density accuracy in specimens where the density is very uniform or as long as measured areas include both earlywood and latewood. An accuracy of +/-2-6 kg/m3 al 95% confidence level can then be expected.
引用
收藏
页码:295 / 299
页数:5
相关论文
共 10 条
[2]  
HATTORI Y, 1985, MOKUZAI GAKKAISHI, V31, P974
[3]  
Herman G.T., 1980, IMAGE RECONSTRUCTION
[4]   COMPUTERIZED TRANSVERSE AXIAL SCANNING (TOMOGRAPHY) .1. DESCRIPTION OF SYSTEM [J].
HOUNDFIELD, GN .
BRITISH JOURNAL OF RADIOLOGY, 1973, 46 (552) :1016-1022
[5]   X-RAY ATTENUATION COEFFICIENTS OF ELEMENTS AND MIXTURES [J].
JACKSON, DF ;
HAWKES, DJ .
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 1981, 70 (03) :169-233
[6]   THE UNRELIABILITY OF CT-NUMBERS AS ABSOLUTE VALUES [J].
LEVI, C ;
GRAY, JE ;
MCCULLOUGH, EC ;
HATTERY, RR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (03) :443-447
[7]  
Lindgren L.O., 1988, NONDESTRUCTIVE MEASU
[9]   3-DIMENSIONAL RECONSTRUCTION FROM RADIOGRAPHS AND ELECTRON MICROGRAPHS - APPLICATION OF CONVOLUTIONS INSTEAD OF FOURIER TRANSFORMS [J].
RAMACHANDRAN, GN ;
LAKSHMINARAYANAN, AV .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1971, 68 (09) :2236-+
[10]  
WELLS P, 1989, INEXPENSIVE XRAY MIC