COLORIMETRIC QUANTIFICATION OF ERYTHEMA - A COMPARISON OF 2 COLORIMETERS (LANGE MICRO COLOR AND MINOLTA CHROMA METER CR-200) WITH A CLINICAL SCORING SCHEME AND LASER-DOPPLER FLOWMETRY

被引:144
作者
SERUP, J
AGNER, T
机构
[1] Department of Dermatology, Rigshospitalet, Copenhagen
关键词
D O I
10.1111/j.1365-2230.1990.tb02087.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Erythema elicited by the local irritant sodium lauryl sulphate was studied in comparison with unexposed skin. Colour coordinates of the CIE system were recorded using two commercially available colorimeters. With both colorimeters a positive movement on the d*‐axis (toward red, P> 0·001) and a negative movement on the L‐axis (toward dark, P>0·01) were registered. Technical and in‐vivo experimentation showed the two pieces of equipment to be accurate. However, a simple conversion factor cannot be established. Both pieces of equipment correlated positively with clinical scoring of erythema and with measurement of cutaneous blood flow by laser‐Doppler flowmetry. In conclusion, the two colorimeters appeared comparable. Colorimetry by the CIE system, which takes into account the non‐linear colour perception of the human eye, was found useful with potential value in both experimental and clinical dermatology. The techniques appeared suitable for routine testing. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:267 / 272
页数:6
相关论文
共 14 条
[1]  
BABULAK SW, 1986, J SOC COSMET CHEM, V37, P475
[2]   A PORTABLE INSTRUMENT FOR QUANTIFYING ERYTHEMA INDUCED BY ULTRAVIOLET-RADIATION [J].
DIFFEY, BL ;
OLIVER, RJ ;
FARR, PM .
BRITISH JOURNAL OF DERMATOLOGY, 1984, 111 (06) :663-672
[3]   EVALUATION OF CUTANEOUS BLOOD-FLOW RESPONSES BY XE-133 WASHOUT AND A LASER-DOPPLER FLOWMETER [J].
ENGELHART, M ;
KRISTENSEN, JK .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1983, 80 (01) :12-15
[4]  
KORNERUP A, 1975, TASCHENLEXIKON FARBE
[5]   NATURAL COLOR SYSTEM - A NEW METHOD FOR EVALUATING SKIN COLORS DURING ARGON-LASER TREATMENT OF PORT-WINE STAIN [J].
MALM, M ;
JURELL, G ;
TONNQUIST, G .
ANNALS OF PLASTIC SURGERY, 1988, 20 (04) :317-321
[6]   ASSESSMENT OF SKIN IRRITANCY IN MAN BY LASER DOPPLER FLOWMETRY [J].
NILSSON, GE ;
OTTO, U ;
WAHLBERG, JE .
CONTACT DERMATITIS, 1982, 8 (06) :401-406
[7]  
Robertson A. R., 1977, COLOR RES APPL, V2, P7, DOI [DOI 10.1002/J.1520-6378.1977.TB00104.X, 10.1002/j.1520-6378.1977.tb00104.x]
[8]   QUANTIFICATION OF WEAL REACTIONS WITH LASER DOPPLER FLOWMETRY - COMPARATIVE BLOOD-FLOW MEASUREMENTS OF THE EDEMATOUS CENTER AND THE PERILESIONAL FLARE OF SKIN-PRICK HISTAMINE WEALS [J].
SERUP, J ;
STABERG, B .
ALLERGY, 1985, 40 (04) :233-237
[9]   QUANTIFICATION OF CUTANEOUS EDEMA IN PATCH TEST REACTIONS BY MEASUREMENT OF SKIN THICKNESS WITH HIGH-FREQUENCY PULSED ULTRASOUND [J].
SERUP, J ;
STABERG, B ;
KLEMP, P .
CONTACT DERMATITIS, 1984, 10 (02) :88-93
[10]   ULTRASOUND FOR ASSESSMENT OF ALLERGIC AND IRRITANT PATCH TEST REACTIONS [J].
SERUP, J ;
STABERG, B .
CONTACT DERMATITIS, 1987, 17 (02) :80-84