DELINEATION OF ACUTE MYOCARDIAL-INFARCTION WITH DYSPROSIUM DTPA-BMA - INFLUENCE OF DOSE OF MAGNETIC-SUSCEPTIBILITY CONTRAST-MEDIUM

被引:23
作者
SAEED, M [1 ]
WENDLAND, MF [1 ]
YU, KK [1 ]
HIGGINS, CB [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,BOX 0628,SAN FRANCISCO,CA 94143
关键词
D O I
10.1016/0735-1097(92)90460-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The contrast enhancement of acutely infarcted myocardium produced by the nonionic magnetic susceptibility-enhancing agent dysprosium diethylenetriamine pentaacetic acid-bis-methylamide (DyDTPA-BMA [S-043 Injection]) was assessed in the current study to establish the lowest dose that would yield optimal contrast between normal and acutely infarcted myocardium. Background. Magnetic susceptibility contrast agents enhance differences between normal and ischemic tissue by reducing the signal of the normally perfused tissue to which they distribute. Methods. Acute myocardial infarctions were produced by ligation of the left coronary artery. At 3 to 4 h after occlusion, a dose of 0.1, 0.3 or 0.5 mmol/kg of DyDTPA-BMA was injected intravenously into eight rats each in group 1, 2 or 3, respectively; a fourth group of seven rats served as a control group. Nuclear magnetic resonance (NMR) transverse relaxation time (T2)-weighted images (electrocardiographically gated to every 5th beat, echo delay time [TE] = 60 ms) were acquired before and for 1 h after administration of contrast agent. Results. Images obtained before the injection of contrast agent showed moderate differences in signal intensity between normal and infarcted myocardium (p < 0.05). The contrast enhancement and the duration of delineation between infarcted and normal myocardium produced by this agent were dose dependent. At doses of 0.1, 0.3 and 0.5 mmol/kg, DyDTPA-BMA produced signal loss in normal myocardium: 63 +/- 5%, 41 +/- 4% and 28 +/- 4% of the baseline values, respectively, without any significant reduction in signal intensity of the infarcted region. The reduction in signal of normal myocardium and delineation of the infarct persisted for 5 min at a dose of 0.1 mmol/kg, for 20 min at a dose of 0.3 mmol/kg and for 40 min at a dose of 0.5 mmol/kg. No change in signal intensity or signal intensity ratio between normal and infarcted myocardium was observed in the control group during the same observation period. Conclusions. These results suggest that low doses of this agent, comparable to those of longitudinal relaxation time (T1)-enhancing agents, can delineate acutely infarcted myocardium. A dose of 0.3 mmol/kg of DyDTPA-BMA (S-043 Injection) provides reasonably persistent demarcation of acute myocardial infarction. Because this dose dramatically suppresses the NMR signal of normal myocardium, it shows the infarcted region as a region of high intensity (bright spot) on NMR images.
引用
收藏
页码:1634 / 1641
页数:8
相关论文
共 28 条
  • [1] BEEN M, 1988, BRIT HEART J, V59, P1
  • [2] MEASUREMENT OF MYOCARDIAL INFARCT SIZE AT EARLY AND LATE TIME INTERVALS USING MR IMAGING - AN EXPERIMENTAL-STUDY IN DOGS
    CAPUTO, GR
    SECHTEM, U
    TSCHOLAKOFF, D
    HIGGINS, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (02) : 237 - 243
  • [3] HIGGINS C B, 1991, American Journal of Cardiac Imaging, V5, P38
  • [4] NUCLEAR MAGNETIC-RESONANCE IMAGING OF ACUTE MYOCARDIAL-INFARCTION IN DOGS - ALTERATIONS IN MAGNETIC-RELAXATION TIMES
    HIGGINS, CB
    HERFKENS, R
    LIPTON, MJ
    SIEVERS, R
    SHELDON, P
    KAUFMAN, L
    CROOKS, LE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (01) : 184 - 188
  • [5] ASSESSMENT OF MYOCARDIAL ISCHEMIA WITH PROTON MAGNETIC-RESONANCE - EFFECTS OF A 3 HOUR CORONARY-OCCLUSION WITH AND WITHOUT REPERFUSION
    JOHNSTON, DL
    BRADY, TJ
    RATNER, AV
    ROSEN, BR
    NEWELL, JB
    POHOST, GM
    OKADA, RD
    [J]. CIRCULATION, 1985, 71 (03) : 595 - 601
  • [6] KANTOR HL, 1989, BOOK ABSTRACTS, V2, P674
  • [7] KANTOR HL, 1990, BOOK ABSTRACTS, V1, P112
  • [8] OCCLUSIVE AND REPERFUSED MYOCARDIAL INFARCTS - MR IMAGING DIFFERENTIATION WITH NONIONIC GD-DTPA-BMA
    MASUI, T
    SAEED, M
    WENDLAND, MF
    HIGGINS, CB
    [J]. RADIOLOGY, 1991, 181 (01) : 77 - 83
  • [9] PETTIGREW RI, 1991, SEMIN ULTRASOUND CT, V12, P61
  • [10] EARLY DETECTION OF CANINE MYOCARDIAL-INFARCTION BY MAGNETIC-RESONANCE IMAGING INVIVO
    PFLUGFELDER, PW
    WISENBERG, G
    PRATO, FS
    CARROLL, SE
    TURNER, KL
    [J]. CIRCULATION, 1985, 71 (03) : 587 - 594