PRESERVING THE HIGH SOURCE BRIGHTNESS WITH X-RAY-BEAM LINE OPTICS (INVITED)

被引:6
作者
BERMAN, LE
机构
关键词
D O I
10.1063/1.1145790
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A first-order challenge facing developers of x-ray beam line optics at synchrotron sources lies in producing optics that faithfully deliver the brightness of the source, especially in the presence of adverse power loads. Once overcome, continued use of beam line optics in experiments often reveals a second-order challenge, that of preservation of the source brightness over time, especially as conditions such as the storage ring current change. This requires maintaining stability, with beam line optics, of the peaks, widths, and centroid positions of the various parameters that contribute to the brightness, the wavelength, position, and angle distributions of the delivered photon beam. Some ideas on the use of x-ray monochromators, mirrors, apertures, and position-sensitive monitors to sense and stabilize the brightness parameter distributions, as well as methods to avoid or minimize transients in the first place, are presented. Examples based on experiences at the X25 wiggler beam line at the National Synchrotron Light Source are given. © 1995 American Institute of Physics.
引用
收藏
页码:2041 / 2047
页数:7
相关论文
共 31 条
[1]   MICROCHANNEL WATER COOLING OF SILICON X-RAY MONOCHROMATOR CRYSTALS [J].
ARTHUR, J ;
TOMPKINS, WH ;
TROXEL, C ;
CONTOLINI, RJ ;
SCHMITT, E ;
BILDERBACK, DH ;
HENDERSON, C ;
WHITE, J ;
SETTERSTEN, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :433-436
[2]  
BERMAN L, 1992, BNL47801 INF REP
[3]   PERFORMANCE OF WATER JET COOLED SILICON MONOCHROMATORS ON A MULTIPOLE WIGGLER BEAM LINE AT NSLS [J].
BERMAN, LE ;
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 300 (02) :415-421
[4]   OPTICAL DESIGN AND PERFORMANCE OF THE X25 HYBRID WIGGLER BEAM LINE AT THE NATIONAL SYNCHROTRON LIGHT-SOURCE [J].
BERMAN, LE ;
HASTINGS, JB ;
OVERSLUIZEN, T ;
WOODLE, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :428-432
[5]   PRESERVING THE HIGH FINESSE OF X-RAY UNDULATOR BEAMS FROM PERFECT WATER-JET-COOLED DIAMOND MONOCHROMATORS [J].
BERMAN, LE ;
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (2-3) :617-620
[6]   DIAMOND CRYSTAL X-RAY OPTICS FOR HIGH-POWER-DENSITY SYNCHROTRON RADIATION BEAMS [J].
BERMAN, LE ;
HASTINGS, JB ;
SIDDONS, DP ;
KOIKE, M ;
STOJANOFF, V ;
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 329 (03) :555-563
[7]  
BERMAN LE, 1993, P SOC PHOTO-OPT INS, V1739, P489, DOI 10.1117/12.140510
[8]   ADAPTIVE CRYSTAL OPTICS FOR UNDULATOR BEAMLINES [J].
BERMAN, LE ;
HART, M ;
SHARMA, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 321 (03) :617-628
[9]   ADAPTIVE CRYSTAL OPTICS FOR HIGH-POWER SYNCHROTRON SOURCES [J].
BERMAN, LE ;
HART, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (03) :558-562
[10]   THE PERFORMANCE OF A SEPARATED CRYSTAL X-RAY MONOCHROMATOR DURING WIGGLER HEATING - PRELIMINARY-RESULTS [J].
BILDERBACK, DH ;
MILLS, DM ;
BATTERMAN, BW ;
HENDERSON, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :428-433