MEASUREMENTS OF RELATIVE HUMIDITY-DEPENDENT BOUNCE AND DENSITY FOR ATMOSPHERIC PARTICLES USING THE DMA-IMPACTOR TECHNIQUE

被引:105
作者
STEIN, SW [1 ]
TURPIN, BJ [1 ]
CAI, XP [1 ]
HUANG, CPF [1 ]
MCMURRY, PH [1 ]
机构
[1] UNIV MINNESOTA,DEPT MECH ENGN,MINNEAPOLIS,MN 55455
关键词
ATMOSPHERIC AEROSOL; DENSITY; AMMONIUM SULFATE; ORGANIC CARBON; PARTICLE BOUNCE; IMPACTOR; MOUDI; RELATIVE HUMIDITY; SIZE DISTRIBUTION; CHEMICAL COMPOSITION;
D O I
10.1016/1352-2310(94)90136-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The dependence of particle bounce on relative humidity in an inertial impactor was measured for atmospheric aerosols in Meadview, AZ, and Minneapolis, MN. An aerosol composed of 0.25 mum atmospheric particles, selected by a differential mobility analyser, was drawn through a single stage of a MOUDI impactor having an aerodynamic cut point of 0.112 mum. The impactor collection efficiency was determined by using two condensation nucleus counters to simultaneously count particles upstream and downstream of the impactor. Bounce measurements were done using uncoated aluminum substrates, and provision was made to control relative humidity of the sampled aerosol. We found that for both locations bounce increased sharply as relative humidities decreased below 60-70%, but little bounce occurred when the relative humidity was maintained above 70 or 80%. Because errors caused by particle bounce and flow-induced relative humidity changes are minimal for relative humidities from 70 to 80%, this is the optimal range for atmospheric sampling with cascade impactors having uncoated stages. Surface loading was found to have a negligible effect on particle bounce for atmospheric particles. A similar apparatus was also used to measure densities of particles in the 0.06-0.18 mum diameter range using the technique described by Kelly and McMurry (Aerosol Sci. Technol. 17, 199-212, 1992). We found that the average density varied between 1.60-and 1.79 g cm-3 (typical uncertainty 4%), and tended to decrease with increasing relative humidity. Measured dry particle densities exceeded the value of 1.48 g cm-3 that was estimated from size-resolved chemical composition measured with MOUDIs.
引用
收藏
页码:1739 / 1746
页数:8
相关论文
共 21 条
[1]   NONIDEAL COLLECTION CHARACTERISTICS OF A CASCADE IMPACTOR WITH VARIOUS COLLECTION SUBSTRATES [J].
BARR, EB ;
NEWTON, GJ ;
YEH, HC .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1982, 16 (09) :633-635
[2]  
CAI X, 1993, 1992 MEASUREMENTS HA
[3]   PARTICLE BOUNCE ERRORS IN CASCADE IMPACTORS [J].
DZUBAY, TG ;
HINES, LE ;
STEVENS, RK .
ATMOSPHERIC ENVIRONMENT, 1976, 10 (03) :229-234
[4]   EFFECT OF FLOW-INDUCED RELATIVE-HUMIDITY CHANGES ON SIZE CUTS FOR SULFURIC-ACID DROPLETS IN THE MICROORIFICE UNIFORM DEPOSIT IMPACTOR (MOUDI) [J].
FANG, CP ;
MCMURRY, PH ;
MARPLE, VA ;
RUBOW, KL .
AEROSOL SCIENCE AND TECHNOLOGY, 1991, 14 (02) :266-277
[5]   DESIGN AND EVALUATION OF A NEW LOW-PRESSURE IMPACTOR .2. [J].
HERING, SV ;
FRIEDLANDER, SK ;
COLLINS, JJ ;
RICHARDS, LW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1979, 13 (02) :184-188
[6]   PARTICLE BOUNCE IN A PERSONAL CASCADE IMPACTOR - A FIELD-EVALUATION [J].
HINDS, WC ;
LIU, WC ;
FROINES, JR .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1985, 46 (09) :517-523
[7]   MEASUREMENT OF PARTICLE DENSITY BY INERTIAL CLASSIFICATION OF DIFFERENTIAL MOBILITY ANALYZER GENERATED MONODISPERSE AEROSOLS [J].
KELLY, WP ;
MCMURRY, PH .
AEROSOL SCIENCE AND TECHNOLOGY, 1992, 17 (03) :199-212
[8]   IMPACTION SURFACE-COATINGS INTERCOMPARISON AND MEASUREMENTS WITH CASCADE IMPACTORS [J].
LAWSON, DR .
ATMOSPHERIC ENVIRONMENT, 1980, 14 (02) :195-199
[9]   EQUILIBRIUM BIPOLAR CHARGE-DISTRIBUTION OF AEROSOLS [J].
LIU, BYH ;
PUI, DYH .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1974, 49 (02) :305-312
[10]  
MARPLE VA, 1986, CASCADE IMPACTOR SAM