UPTAKE AND LOSS OF TEARS FROM FILTER-PAPER DISKS EMPLOYED IN LYSOZYME TESTS

被引:7
作者
HYPHER, TJ [1 ]
机构
[1] UNIV LIVERPOOL,DEPT OPHTHALMOL,LIVERPOOL L69 3BX,MERSEYSIDE,ENGLAND
关键词
D O I
10.1136/bjo.63.4.251
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aspects of the use of filter paper discs in collecting tear samples for lysozyme tests were studied by serial weighings of bijoux bottles and tear moistened discs. Blotted discs carried from 1.9 to 3.6 mg tears, but for practical purposes no deposit was left in the bottle. Unblotted discs carried a greater quantity of tear fluid, but the majority deposited a proportion of this in the bottle, and a correcting factor is therefore proposed for the lysozyme assay technique of Mackie and Seal. Substantial vaporisation of tears occurred within the bottles.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 6 条
[1]  
BIJSTERVELD OP, 1969, ARCH OPHTHALMOL-CHIC, V82, P10
[2]   HUMAN TEAR LYSOZYME .2. QUANTITATIVE DETERMINATION WITH STANDARD SCHIRMER STRIPS [J].
BONAVIDA, B ;
SAPSE, AT .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1968, 66 (01) :70-&
[3]   BETA-ADRENERGIC-RECEPTOR BLOCKING-DRUGS - TEAR LYSOZYME AND IMMUNOLOGICAL SCREENING FOR ADVERSE REACTION [J].
MACKIE, IA ;
SEAL, DV ;
PESCOD, JM .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1977, 61 (05) :354-359
[4]   QUANTITATIVE TEAR LYSOZYME ASSAY IN UNITS OF ACTIVITY PER MICROLITER [J].
MACKIE, IA ;
SEAL, DV .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1976, 60 (01) :70-74
[5]  
PIETSCH RL, 1973, ARCH OPHTHALMOL-CHIC, V90, P94
[6]  
Siegel S., 1956, NONPARAMETRIC STAT, P127